Back to Search
Start Over
Accuracy of digital and conventional dental implant impressions for fixed partial dentures: a comparative clinical study
- Source :
- Journal of advanced prosthodontics, Seoul : Korean Academy of Prosthodontics, 2019, vol. 11, iss. 5, p. 271-279, The Journal of Advanced Prosthodontics
- Publication Year :
- 2019
-
Abstract
- Purpose The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. Materials and methods Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. Results Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and dist al implant scan bodies (P≤.05). Conclusion Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.
- Subjects :
- Orthodontics
Scanner
Dental implant
Computer science
medicine.medical_treatment
0206 medical engineering
High resolution
Digital impression
030206 dentistry
02 engineering and technology
020601 biomedical engineering
Impression
Clinical study
03 medical and health sciences
0302 clinical medicine
dental implant
digital impression
impression accuracy
Fixed partial dentures
medicine
Original Article
Dentistry (miscellaneous)
Implant
Oral Surgery
Impression accuracy
Rotation (mathematics)
Subjects
Details
- Language :
- English
- ISSN :
- 20057806 and 20057814
- Database :
- OpenAIRE
- Journal :
- Journal of advanced prosthodontics, Seoul : Korean Academy of Prosthodontics, 2019, vol. 11, iss. 5, p. 271-279, The Journal of Advanced Prosthodontics
- Accession number :
- edsair.doi.dedup.....c3871e5100947e803976477224a0b407