Back to Search
Start Over
A Temperature-Risk and Energy-Saving Evaluation Model for Supporting Energy-Saving Measures for Data Center Server Rooms
- Source :
- Energies, Vol 13, Iss 5222, p 5222 (2020), Energies; Volume 13; Issue 19; Pages: 5222
- Publication Year :
- 2020
- Publisher :
- MDPI AG, 2020.
-
Abstract
- As data centers have become increasingly important in recent years their operational management must attain higher efficiency and reliability. Moreover, the power consumption of a data center is extremely large, and it is anticipated that it will continue to increase, so energy saving has become an urgent issue concerning data centers. In the meantime, the environment of the server rooms in data centers has become complicated owing to the introduction of virtualization technology, the installation of high-heat density information and communication technology (ICT) equipment and racks, and the diversification of cooling methods. It is very difficult to manage a server room in the case of such a complicated environment. When energy-saving measures are implemented in a server room with such a complicated environment, it is important to evaluate “temperature risks” in advance and calculate the energy-saving effect after the measures are taken. Under those circumstances, in this study, two prediction models are proposed: a model that predicts the rack intake temperature (so that the temperature risk can be evaluated in support of energy-saving measures implemented in the server room) and a model that evaluates the energy-saving effect (in relation to a baseline). Specifically, the models were constructed by using machine learning. The first constructed model evaluates the temperature risk in a verification room in advance, and it was confirmed that the model can evaluate the risk beforehand with high accuracy. The second constructed model—“baseline model” hereafter—supports energy-saving measures, and it was confirmed that the model can calculate the baseline (energy consumption) with high accuracy as well. Moreover, the effect of proposal process of energy-saving measures in the verification room was verified by using the two proposed models. In particular, the effectiveness of the model for evaluating temperature risk in advance and that of a technology for visualizing the energy-saving effect were confirmed.
- Subjects :
- Control and Optimization
Relation (database)
Computer science
Energy Engineering and Power Technology
energy simulation
data center
computer.software_genre
lcsh:Technology
Electrical and Electronic Engineering
Baseline (configuration management)
Server room
Engineering (miscellaneous)
Reliability (statistics)
temperature prediction
baseline
machine learning
server room
temperature environment
energy saving
continuous and reliable operation
lcsh:T
Renewable Energy, Sustainability and the Environment
business.industry
Energy consumption
Virtualization
Reliability engineering
Data center
business
computer
Energy (miscellaneous)
Subjects
Details
- ISSN :
- 19961073
- Volume :
- 13
- Database :
- OpenAIRE
- Journal :
- Energies
- Accession number :
- edsair.doi.dedup.....c2abffeab0761d2ff9973d8d2068854e