Back to Search
Start Over
Image-guided radiotherapy for prostate cancer using 3 different techniques: localization data of 186 patients
- Source :
- Tumori. 101(3)
- Publication Year :
- 2015
-
Abstract
- Aims and Background This study evaluates 3 different imaging modalities—ultrasound (US), stereoscopic X-ray imaging of implanted markers (Visicoils) (X-ray), and kV cone-beam computed tomography (CBCT)—to assess interfraction and intrafraction localization error during conformal radiation therapy of prostate cancer. Methods and Study Design The study population consisted of 186 consecutive prostate cancer patients treated with an image-guided radiotherapy (IGRT) hypofractionated protocol using 3 techniques: 32 with X-ray, 30 with CBCT, and 124 with US. Treatment dose of 70.2 Gy was delivered in 26 fractions with a conformal dynamic arcs technique. Interfraction prostate localization errors were determined for the 3 techniques. Moreover, interfraction and intrafraction prostate motion in terms of translations and rotations, as well as residual errors, were determined with X-ray. Results The systematic and random components of the prostate localization errors were as follows: ( 1 ) with X-ray 3.0 ± 3.4, 2.3 ± 2.7, 1.8 ± 2.3 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions and 1.8° ± 1.2°, 2.3° ± 1.5°, 2.7° ± 3.1°, for the yaw, roll, and pitch rotations; ( 2 ) with CBCT3.5 ± 4.2, 3.3 ± 3.3, 2.5 ± 3.1 mm in AP, SI, and LR directions; ( 3 ) with US 3.7 ± 4.7, 3.4 ± 4.3, 2.3 ± 3.5 mm in AP, SI, and LR directions. Residual errors with X-ray were less than 1 mm in all directions. Intrafraction prostate motion of less than 0.5 mm in LR and of the order of 1 mm in AP and SI directions was found. This led to a significant reduction of the margins, potentially important for dose escalation studies. Conclusions Daily on-line IGRT with stereoscopic X-ray imaging allowed a consistent PTV margin reduction considering residual interfraction prostate localization error and intrafraction motion. X-ray offers the best compromise among accuracy, reliability, dose to the patient, and time investment for daily IGRT treatment of prostate.
- Subjects :
- Male
Cancer Research
medicine.medical_specialty
Cone beam computed tomography
Treatment outcome
Radiotherapy image guided
Computed tomography
Image guided radiotherapy
Prostate cancer
Text mining
medicine
Humans
Medical physics
Ultrasonography, Interventional
Aged
medicine.diagnostic_test
business.industry
Radiotherapy Planning, Computer-Assisted
Dose fractionation
Prostatic Neoplasms
General Medicine
Cone-Beam Computed Tomography
medicine.disease
Treatment Outcome
Oncology
Radiology
Dose Fractionation, Radiation
business
Radiotherapy, Image-Guided
Subjects
Details
- ISSN :
- 20382529
- Volume :
- 101
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Tumori
- Accession number :
- edsair.doi.dedup.....c2a816380778ea0a884541ccd50699df