Back to Search
Start Over
Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze
- Source :
- Acta stomatologica Croatica : International journal of oral sciences and dental medicine, Volume 51, Issue 4, Acta Stomatologica Croatica, Acta Stomatologica Croatica, Vol 51, Iss 4, Pp 309-315 (2017)
- Publication Year :
- 2017
- Publisher :
- School of Dental Medicine, University of Zagreb, Croatian Dental Society - Croatian Medical Association, 2017.
-
Abstract
- Svrha: Svrha ovoga rada bila je procijeniti utjecaj termocikliranja na čvrstoću savijanja poliamidnog materijala za bazu proteze. Materijali i metode: Testiran je poliamidni protezni materijal (Valplast), a kao kontrola korišten je PMMA (Vertex). Trideset primjeraka svakog materijala izrađeno je za ispitivanje čvrstoće savijanja prema standardu ISO 1567. Svi su uzorci pripremljeni i čuvani 48 sati u vodi na temperaturi od 37 °C, a zatim su podijeljeni u tri jednake skupine (n = 10). Ispitivanje čvrstoće savijanja obavljeno je odmah nakon uranjanja u vodu te nakon termocikliranja (5 °C/55 °C, 2c/min.) poslije 3000 i 5000 ciklusa. Ispitivanje fleksibilnosti provedeno je na trima točkama u univerzalnom stroju za testiranje na brzini križanja od 5 mm/min. Konačna čvrstoća savijanja izračunata je formulom: FS = 3PL/2bd2. Dvosmjerna ANOVA s Tukeyjevim post hoc testom primijenjena je na razini .05 statističke značajnosti. Rezultati: tatistički značajno smanjenje čvrstoće savijanja zabilježeno je nakon termocikliranja poslije 3000 ciklusa za PMMA-e i 5000 ciklusa za oba materijala. Čvrstoća savijanja PMMA-e bila je značajno veća u odnosu na poliamid za sve ispitane uvjete (p < 0,05). Zaključak: Termocikliranje je vrlo nepovoljno djelovalo na čvrstoću savijanja materijala poliamida i materijala PMMA za bazu proteze.<br />Objective: The aim of the present study was to evaluate the influence of thermocycling on the flexural strength of a polyamide base denture material. Materials and methods: A polyamide denture base material (Valplast) was tested, whereas a PMMA material (Vertex) was used as a control. Thirty specimens of each material were fabricated for flexural strength testing according to ISO 1567. They were prepared and stored in water at 37°C for 48 hours. The specimens of each material were divided into three equal groups (n=10). Flexural strength testing was performed immediately after water storage and after thermocycling (5°C / 55°C, 2 c/min) for 3000 and 5000 cycles. A three point flexural test was performed on a universal testing machine at a crosshead speed of 5 mm/min. The final flexural strength was calculated using the formula: FS = 3 PL/2 bd2. A two-way ANOVA with post-hoc analysis using Tukey’s procedure was applied at .05 level of statistical significance. Results: A statistically significant reduction in flexural strength was recorded after thermocycling at 3000 cycles for PMMA and at 5000 cycles for both materials. The flexural strength of PMMA was significantly higher compared to polyamide for all the conditions tested (p
- Subjects :
- Materials science
Three point flexural test
02 engineering and technology
Materials testing
Crosshead
Denture bases
Flexural Strength
Resins, Synthetic
Polyamide
Nylons
Materials Testing
03 medical and health sciences
0302 clinical medicine
Flexural strength
zubna proteza, baza
čvrstoća na savijanje
smole, sintetičke
poliamid
najlon
materijali, testiranje
Composite material
Original Scientific Papers
General Dentistry
Universal testing machine
030206 dentistry
021001 nanoscience & nanotechnology
lcsh:RK1-715
lcsh:Dentistry
Denture base
0210 nano-technology
Subjects
Details
- Language :
- English
- ISSN :
- 18460410 and 00017019
- Volume :
- 51
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Acta stomatologica Croatica : International journal of oral sciences and dental medicine
- Accession number :
- edsair.doi.dedup.....c0a76b3577de6eac4a73171b4b038aa4