Back to Search Start Over

Coupling a CLOVER detector array with the PRISMA magnetic spectrometer - Investigation of moderately neutron-rich nuclei populated by multinucleon transfer and deep inelastic collisions

Authors :
Gadea, A.
Napoli, D. R.
Angelis, G.
Menegazzo, R.
Stefanini, A. M.
Corradi, L.
Axiotis, M.
Berti, L.
Fioretto, E.
Kroell, T.
Latina, A.
Marginean, N.
Maron, G.
Martinez, T.
Rosso, D.
Rusu, C.
Toniolo, N.
Szilner, S.
Trotta, M.
Bazzacco, D.
Beghini, S.
Bellato, M.
Brandolini, F.
Farnea, E.
Isocrate, R.
Lenzi, S. M.
Lunardi, S.
Montagnoli, G.
Pavan, P.
Rossi, Alvarez
Scarlassara, C.
Ur, F.
Blasi, C.
Bracco, N.
Camera, A.
Leoni, F.
Million, S.
Pignanelli, B.
Pollarolo, Giovanni
Derosa, G.
Inglima, A.
Commara, G.
Rana, M.
Pierroutsakou, G.
Romoli, D.
Sandoli, M.
Bizzeti, M.
P. G.
Bizzeti, Sona
A. M.
Bianco, Lo
Petrache, G.
C. M., Zucchiatti
Cocconi, A.
Quintana, P.
Beck, B.
Curien, Ch
Duchene, D.
Haas, G.
Medina, F.
Papka, P.
Durell, P.
Freeman, J.
S. J., Smith
Varley, A.
Fayz, B.
Pucknell, K.
Simpson, V.
Gelletly, J.
Regan, W.
Gadea, A.
Napoli, D. R.
De Angelis, G.
Menegazzo, R.
Stefanini, A. M.
Corradi, L.
Axiotis, M.
Berti, L.
Fioretto, E.
Kroell, T.
Latina, A.
Marginean, N.
Maron, G.
Martinez, T.
Rosso, D.
Rusu, C.
Toniolo, N.
Szilner, S.
Trotta, M.
Bazzacco, D.
Beghini, S.
Bellato, M.
Brandolini, F.
Farnea, E.
Isocrate, R.
Lenzi, S. M.
Lunardi, S.
Montagnoli, G.
Pavan, P.
Alvarez, C. Rossi
Scarlassara, F.
Ur, C.
Blasi, N.
Bracco, A.
Camera, F.
Leoni, S.
Million, B.
Pignanelli, M.
Pollarolo, G.
Derosa, A.
Inglima, G.
LA COMMARA, Marco
LA RANA, Giovanni
Pierroutsakou, D.
Romoli, M.
Sandoli, M.
Bizzeti, P. G.
Bizzeti Sona, A. M.
Lo Bianco, G.
Petrache, C. M.
Zucchiatti, A.
Cocconi, P.
Quintana, B.
Beck, C. h.
Curien, D.
DuchĂȘne, G.
Haas, F.
Medina, P.
Papka, P.
Durell, J.
Freeman, S. J.
Smith, A.
Varley, B.
Fayz, K.
Pucknell, V.
Simpson, J.
Gelletly, W.
Regan, P.
Source :
University of Manchester-PURE

Abstract

Following the commissioning of the PRISMA large-acceptance spectrometer, installed at the Laboratori Nazionali di Legnaro (LNL), an international nuclear-structure collaboration has started to develop a large $\gamma$ -ray setup to be installed in the target position of the spectrometer. The array is based on the EUROBALL composite CLOVER detectors. In this contribution the CLOVER detector array is described and its expected performance figures discussed. This new setup, by using the high-intensity heavy-ion beams provided by the LNL ALPI linac, will push the study of nuclear structure towards moderately neutron-rich nuclei by means of quasi-elastic and deep inelastic reactions.

Details

Database :
OpenAIRE
Journal :
University of Manchester-PURE
Accession number :
edsair.doi.dedup.....bfc75126d3cd0830ad8bd8722b5ec87f