Back to Search Start Over

Mandibular Reconstruction with Bridging Customized Plate after Ablative Surgery for ONJ: A Multi-Centric Case Series

Authors :
Francesco Ricotta
Alberto Bianchi
Fabio Michelon
Rosalia Mineo
Claudio Marchetti
Salvatore Crimi
Salvatore Battaglia
Achille Tarsitano
Battaglia S.
Ricotta F.
Crimi S.
Mineo R.
Michelon F.
Tarsitano A.
Marchetti C.
Bianchi A.
Source :
Applied Sciences; Volume 11; Issue 22; Pages: 11069, Applied Sciences, Vol 11, Iss 11069, p 11069 (2021)
Publication Year :
2021
Publisher :
Multidisciplinary Digital Publishing Institute, 2021.

Abstract

Purpose: Computer-aided methods for mandibular reconstruction have improved both functional and morphological results in patients who underwent segmental mandibular resection. The purpose of this study is to evaluate the overlaying of virtual planning in terms of measures of the Computer Assisted Design/Computer Assisted Manufacturing CAD/CAM plate for mandibular reconstruction in patients who are ineligible for the insertion of reconstructing the titanium plate supported by fibular free flap, due to their poor health status, or in the presence of specific contraindications to autologous bone flap harvest. Materials and methods: The retrospective study performed analyzed the results of nine patients. The patients were treated at the Maxillofacial Surgery Unit of Policlinico S. Orsola of Bologna, Italy, and Policlinico San Marco, Catania, Italy, from April 2016 to June 2021. Superimposition between planning and post operative Computed Tomography CT scan was performed to assess the accuracy. Results: All reconstructive procedures were carried out successfully. No microsurgery-related complications occurred. In two cases, we had plate misplacement, and in one case, plate exposure that led to plate removal. The average accuracy of the series assessed after CT superimposition, as previously described, was 0.95 mm. Conclusions: Considering that microvascular bone transfer is a high-risk procedure in BRONJ patients, we can conclude that the positioning of a customized bridging mandibular prosthesis (CBMP), whether or not it is associated with a microvascular soft tissue transfer, is a safe technique in terms of surgical outcome and feasibility.

Details

Language :
English
ISSN :
20763417
Database :
OpenAIRE
Journal :
Applied Sciences; Volume 11; Issue 22; Pages: 11069
Accession number :
edsair.doi.dedup.....bee8c6f30c6ed62fafe83474829527ed
Full Text :
https://doi.org/10.3390/app112211069