Back to Search
Start Over
Control of fouling formation in membrane ultrafiltration by ultrasound irradiation
- Source :
- The Lens
-
Abstract
- The increasing application of membrane filtration in water and wastewater treatment necessitates techniques to improve performance, especially in fouling control. Ultrasound is one promising technology for this purpose as cavitational effects facilitate continuous cleaning of the membrane. This research studied the ultrafiltration of lake water in systems with constant permeate flux under medium frequency (45 kHz) ultrasound irradiation. Fouling was investigated by monitoring transmembrane pressure (TMP) using continuous or intermittent ultrasound irradiation and dead-end or crossflow operation. Best performance was observed with continuous ultrasound irradiation in crossflow mode. Intermittent irradiation reduced the rate of TMP build-up but nevertheless allowed irreversible fouling to develop.
- Subjects :
- sonication
Materials science
fouling
Biofouling
Sonication
Ultrafiltration
Water Purification
law.invention
NOM
membrane ultrafiltration
ultrasound
law
Environmental Chemistry
Ultrasonics
Irradiation
Waste Management and Disposal
Filtration
Water Science and Technology
Chromatography
Fouling
business.industry
Ultrasound
Membrane fouling
Membranes, Artificial
General Medicine
Membrane
Chemical engineering
business
Subjects
Details
- Database :
- OpenAIRE
- Journal :
- The Lens
- Accession number :
- edsair.doi.dedup.....be7b0be72c76f8d4252a64a1055e4ca7