Impact of EBUS-TBNA in addition to [18F]FDG-PET/CT imaging on target volume definition for radiochemotherapy in stage III NSCLC

Authors :
Hubertus Hautzel
Lale Umutlu
Rüdiger Karpf-Wissel
Axel Wetter
Nika Guberina
Dirk Theegarten
Martin Stuschke
Maja Guberina
Wilfried Eberhardt
Martin Schuler
Clemens Aigner
Ken Herrmann
Till Ploenes
Kaid Darwiche
Christoph Pöttgen
Source :
European Journal of Nuclear Medicine and Molecular Imaging
Publication Year :
2021
Publisher :
Springer Berlin Heidelberg, 2021.

Abstract

Purpose/introduction [18F]FDG-PET/CT is the standard imaging-technique for radiation treatment (RT) planning in locally advanced non-small cell lung cancer (NSCLC). The purpose of this study was to examine the additional value of endobronchial-ultrasound transbronchial needle aspiration (EBUS-TBNA) to standard PET/CT for mediastinal lymph-node (LN) staging and its impact on clinical target volume (CTV). Materials and methods All consecutive patients with primary stage III NSCLC who underwent [18F]FDG-PET/CT and EBUS-TBNA prior to RT were analyzed from 12/2011 to 06/2018. LN-stations were assessed by an expert-radiologist and a nuclear medicine-physician. CTV was evaluated by two independent radiation oncologists. LNs were grouped with increasing distance along the lymphatic chains from primary tumor into echelon-1 (ipsilateral hilum), echelon-2 (LN-station 7 and ipsilateral 4), and echelon-3 (remaining mediastinum and contralateral hilum). Results A total of 675 LN-stations of which 291 were positive for tumor-cells, were sampled by EBUS-TBNA in 180 patients. The rate of EBUS-positive LNs was 43% among all sampled LNs. EBUS-positivity in EBUS-probed LNs decreased from 85.8% in echelon-1 LNs to 42.4%/ 9.6% in echelon-2/ -3 LNs, respectively (p < 0.0001, Fisher’s exact test). The false discovery rate of PET in comparison with EBUS results rose from 5.3% in echelon-1 to 32.9%/ 69.1% in echelon-2/ -3 LNs, respectively (p < 0.0001, Fisher’s exact test). Sensitivity and specificity of FDG-PET/CT ranged from 85 to 99% and 67 to 80% for the different echelons. In 22.2% patients, EBUS-TBNA finding triggered changes of the treated CTV, compared with contouring algorithms based on FDG-avidity as the sole criterion for inclusion. CTV was enlarged in 6.7% patients due to EBUS-positivity in PET-negative LN-station and reduced in 15.5% by exclusion of an EBUS-negative but PET-positive LN-station. Conclusion The false discovery rate of [18F]FDG-PET/CT increased markedly with distance from the primary tumor. Inclusion of systematic mediastinal LN mapping by EBUS-TBNA in addition to PET/CT has the potential to increase accuracy of target volume definition, particularly in echelon-3 LNs. EBUS-TBNA is recommended as integral part of staging for radiochemotherapy in stage III NSCLC.

Details

Language :
English
ISSN :
16197089 and 16197070
Volume :
48
Issue :
9
Database :
OpenAIRE
Journal :
European Journal of Nuclear Medicine and Molecular Imaging
Accession number :
edsair.doi.dedup.....bcdd1251be5a8c906953420392bea89f