Back to Search
Start Over
Diagnosis of incomplete conduction block of spinal cord from skin surface using spinal cord evoked magnetic fields
- Source :
- Journal of Orthopaedic Science. 15:371-380
- Publication Year :
- 2010
- Publisher :
- Elsevier BV, 2010.
-
Abstract
- Background We previously reported the usefulness of neuromagnetic recordings for the diagnosis of disorders in peripheral nerves or the spinal cord. However, there have been no reports on incomplete conduction block of the spinal cord, which is clinically common in conditions such as cervical myelopathy. Here, we estimated the usefulness of measuring spinal cord evoked magnetic fi elds for evaluating incomplete conduction block. Methods Incomplete conduction block models of the spinal cord of the rabbit were established using a Fogarty balloon catheter that was inserted into the epidural space of the cervical spine. Electrical stimuli were applied to the lower thoracic spinal cord with an epidural catheter electrode. Spinal cord evoked potentials were recorded using epidural electrodes. Spinal cord evoked magnetic fi elds were recorded over the skin surface of the neck using a biomagnetometer. Results The decrease in the conduction velocity and amplitude at the compression site could be detected by spinal cord evoked potentials from the epidural space, confi rming the spinal cord lesion. The waveforms of the magnetic fi elds showed a biphasic confi guration. The distribution of magnetic fi elds showed a characteristic quadrupolar pattern propagating from caudal to cranial. After compression, the amplitude and the conduction velocity of the magnetic fi elds decreased, and the distribution of magnetic fi elds were attenuated and decelerated near the compression site especially in the trailing magnetic fi elds. Diagnosis of the incomplete conduction block was thus possible. Conclusions We report the fi rst measurement of the spinal cord evoked magnetic fi eld in the intact spinal cord from the skin surface and that it can be applied to incomplete conduction block of the injured spinal cord. The use of a biomagnetometer is promising as a less-invasive method for clinically evaluating spinal cord function.
- Subjects :
- Neural Conduction
business.industry
Electrodiagnosis
Nerve Compression Syndromes
Balloon catheter
Anatomy
Evoked Potentials, Motor
medicine.disease
Spinal cord
Nerve conduction velocity
Epidural space
Nerve compression syndrome
Disease Models, Animal
Myelopathy
Electromagnetic Fields
medicine.anatomical_structure
Spinal cord compression
medicine
Animals
Orthopedics and Sports Medicine
Surgery
Rabbits
business
Spinal Cord Compression
Subjects
Details
- ISSN :
- 09492658
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- Journal of Orthopaedic Science
- Accession number :