Back to Search
Start Over
Is volar locking plate superior to external fixation for distal radius fractures? A comprehensive meta-analysis
- Source :
- Acta Orthopaedica et Traumatologica Turcica, Vol 52, Iss 5, Pp 334-342 (2018), Acta Orthopaedica et Traumatologica Turcica
- Publication Year :
- 2018
-
Abstract
- Objective: The aim of this meta-analysis of randomized controlled trials (RCT) and retrospective cohort studies (CS) regarding the use of volar locking plate (VLP) and external fixation (EF) in distal radius fractures was to determine whether there was any evidence that one treatment was superior to the other. Methods: The meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Electrical databases (PubMed, EMBASE and the Cochrane library) were retrieved to find RCTs and CSs met the eligibility criteria. Two reviewers screened the studies, extracted the data and evaluated the methodological quality, and performed data analysis with RevMan 5.1. The publication bias was test by Stata 14.0. The Begg's and Egger's test were performed by Stata 14.0. The quality of evidence was graded according to the criteria of GRADE. We ultimately included ten RCTs and eleven CSs. Results: A total of 1590 subjects were reported. Publication bias was detected by funnel plot in RCTs. VLP could provide better results such as DASH scores (RCT: MD = −6.12, 95%CI = −12.07–0.17; CS: MD = −6.43, 95%CI = −12.53–0.3), ulnar variance (RCT: MD = −0.81, 95%CI = −1.25–0.37) and infection rate (RCT: RR = 0.25, 95%CI = 0.10–0.65; CS: RR = 0.15, 95%CI = 0.06–0.40). There were no significant differences for G-W scores, VAS and grip strength between the VLP group and EF group. There was significantly greater loss of volar tilt (P = 0.01) and radial inclination (P = 0.02) in patients receiving EF, basing on the CSs. Conclusions: VLP could provide better results, such as DASH scores, ulnar variance, volar tilt, radial inclination and infection rate. The use of VLP appear to be associated with better results of ROM (flexion, pronation, supination and radial deviation), radiographic parameters (volar tilt and radial inclination) and lower total complication rate and CRPS rate in CSs. Level of evidence: Level 1, Therapeutic study. Keywords: Distal radial fractures, Volar locking plate, External fixation, Meta-analysis, GRADE analysis
- Subjects :
- Funnel plot
External Fixators
medicine.medical_treatment
Ilizarov Technique
Cochrane Library
law.invention
03 medical and health sciences
External fixation
Grip strength
0302 clinical medicine
Randomized controlled trial
lcsh:Orthopedic surgery
law
Dash
medicine
Humans
Orthopedics and Sports Medicine
030212 general & internal medicine
GRADE analysis
Orthodontics
030222 orthopedics
business.industry
General Medicine
Publication bias
Volar locking plate
Meta-analysis
lcsh:RD701-811
Treatment Outcome
Distal radial fractures
Surgery
business
Radius Fractures
Bone Plates
Research Paper
Subjects
Details
- ISSN :
- 25891294
- Volume :
- 52
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Acta orthopaedica et traumatologica turcica
- Accession number :
- edsair.doi.dedup.....bb7c4e83640d52aa9c35e558ca5f2749