Back to Search
Start Over
Effect of percutaneous interventions within the coronary sinus on the success rate of the implantations of resynchronization pacemakers
- Source :
- Pacing and clinical electrophysiology : PACE. 29(10)
- Publication Year :
- 2006
-
Abstract
- Background: Cardiac resynchronization therapy (CRT) becomes a “gold standard” in therapy of selected patients with advanced heart failure. We set out to evaluate the feasibility and safety of percutaneous interventions within coronary sinus (CS) and their effect on the success rate of left ventricular (LV) lead implantation during CRT. Methods: The study analyzed eight consecutive patients with the indications for CRT, who needed additional procedures within CS to overcome technical problems during left ventricular (LV) electrode implantation. The analyzed group consisted of three subgroups: patients in whom percutaneous balloon angioplasty within CS was needed (n = 4); patients with acute instability of the lead, requiring stenting of the vein to fix the electrode (n = 2); and patients with the stenting of CS due to late dislocation of the lead (n = 2). Success rate, procedure duration, fluoroscopy, complications, and electrical parameters of leads were analyzed. Results: Success rate of the procedures was 87.5%; additional interventions increased overall efficacy of CRT implantation at our center from 88% to 98% (P < 0.05). Procedure duration (155.0 minute) and fluoroscopy time (42.5 minute) remained acceptable for the patient and operator; however, both were higher than in the procedures performed routinely in our hospital. Electrical properties of the LV leads were stable and within normal ranges during the observation period. We noted two local dissections of CS during the procedure, which remained clinically silent. Conclusion: Percutaneous interventions within CS seem to be feasible and safe treatment options, which can improve the short- and long-term success rates of CRT.
- Subjects :
- Adult
Male
medicine.medical_specialty
Pacemaker, Artificial
Percutaneous
medicine.medical_treatment
Cardiac resynchronization therapy
Internal medicine
medicine
Fluoroscopy
Humans
Angioplasty, Balloon, Coronary
Lead (electronics)
Vein
Coronary sinus
Aged
Heart Failure
medicine.diagnostic_test
business.industry
Gold standard
General Medicine
Middle Aged
medicine.disease
Coronary Vessels
Surgery
medicine.anatomical_structure
Heart failure
Cardiology
Feasibility Studies
Female
Stents
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 01478389
- Volume :
- 29
- Issue :
- 10
- Database :
- OpenAIRE
- Journal :
- Pacing and clinical electrophysiology : PACE
- Accession number :
- edsair.doi.dedup.....bb1b9d4c9dc69a651ece3c8077a91d25