Back to Search
Start Over
Chandra follow-up of the Hectospec Cluster Survey: comparison of caustic and hydrostatic masses and constraints on the hydrostatic bias
- Source :
- Logan, C H A, Maughan, B J, Diaferio, A, Duffy, R T, Geller, M J, Rines, K & Sohn, J 2022, ' Chandra follow-up of the Hectospec Cluster Survey : Comparison of caustic and hydrostatic masses and constraints on the hydrostatic bias ', Astronomy and Astrophysics, vol. 665, A124 . https://doi.org/10.1051/0004-6361/202243347
- Publication Year :
- 2022
-
Abstract
- Clusters of galaxies are powerful probes with which to study cosmology and astrophysics. However, for many applications an accurate measurement of a cluster's mass is essential. A systematic underestimate of hydrostatic masses from X-ray observations (the so-called hydrostatic bias) may be responsible for tension between the results of different cosmological measurements. We compare X-ray hydrostatic masses with masses estimated using the caustic method (based on galaxy velocities) in order to explore the systematic uncertainties of both methods and place new constraints on the level of hydrostatic bias. Hydrostatic and caustic mass profiles were determined independently for a sample of 44 clusters based on Chandra observations of clusters from the Hectospec Cluster Survey. This is the largest systematic comparison of its kind. Masses were compared at a standardised radius ($R_{500}$) using a model that includes possible bias and scatter in both mass estimates. The systematics affecting both mass determination methods were explored in detail. The hydrostatic masses were found to be systematically higher than caustic masses on average, and we found evidence that the caustic method increasingly underestimates the mass when fewer galaxies are used to measure the caustics. We limit our analysis to the 14 clusters with the best-sampled caustics where this bias is minimised ($\ge210$ galaxies), and find that the average ratio of hydrostatic to caustic mass at $R_{500}$ is $M_X/M_C=1.12^{+0.11}_{-0.10}$. We interpret this result as a constraint on the level of hydrostatic bias, favouring small or zero levels of hydrostatic bias (less than $20\%$ at the $3\sigma$ level). However, we find systematic uncertainties associated with both mass estimation methods remain at the $10-15\%$ level, which would permit significantly larger levels of hydrostatic bias.<br />Comment: 15 pages plus appendices. Updated to match version accepted for publication in A&A. Updates include additional tests of systematics. Main results are unchanged
- Subjects :
- Cosmology and Nongalactic Astrophysics (astro-ph.CO)
astro-ph.GA
FOS: Physical sciences
Astronomy and Astrophysics
Astrophysics - Astrophysics of Galaxies
Space and Planetary Science
galaxies: clusters: general
galaxies: kinematics and dynamics
cosmology: observations
X-rays: galaxies: clusters
Astrophysics of Galaxies (astro-ph.GA)
astro-ph.CO
Astrophysics - Cosmology and Nongalactic Astrophysics
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Logan, C H A, Maughan, B J, Diaferio, A, Duffy, R T, Geller, M J, Rines, K & Sohn, J 2022, ' Chandra follow-up of the Hectospec Cluster Survey : Comparison of caustic and hydrostatic masses and constraints on the hydrostatic bias ', Astronomy and Astrophysics, vol. 665, A124 . https://doi.org/10.1051/0004-6361/202243347
- Accession number :
- edsair.doi.dedup.....ba9f3c25ed6d10237724eeb14f3f3134
- Full Text :
- https://doi.org/10.1051/0004-6361/202243347