Back to Search Start Over

Prospective Registry of Embolization of Intracranial Aneurysms Using HydroSoft Coils: Results of the Japanese HydroSoft Registry

Authors :
Hirotoshi Imamura
Nobuyuki Sakai
Yasushi Ito
Chiaki Sakai
Akio Hyodo
Shigeru Miyachi
Yuji Matsumaru
Shinichi Yoshimura
Toshi Abe
Hiroshi Yamagami
Mikito Hayakawa
Hiroaki Sato
Toshiyuki Fujinaka
Kenichiro Tanabe
Koichi Haraguchi
Makoto Sakamoto
Masashi Morimoto
Toshio Higashi
Kenji Sugiu
Akira Ishii
Ichiro Nakahara
Hidenori Oishi
Yasushi Matsumoto
Yasunari Niimi
Hirokatsu Yonaha
Yukiko Enomoto
Tomoshi Iinoshi
Masahiko Kawanishi
Satoshi Ushikoshi
Naoki Toma
Sadanori Kiura
Mitshuhito Mase
Takashi Izumi
Source :
World neurosurgery. 127
Publication Year :
2018

Abstract

The effect of HydroSoft coils on the prevention of recanalization and thrombosis after embolization is unclear. We herein report the results of the single-armed prospective Japanese HydroSoft Registry.Aneurysms with a diameter of10 mm that were treated with a ≥50% length of HydroSoft coils were registered. We evaluated the safety and recanalization rate and analyzed the factors related to their recanalization and thrombosis 1 year later.In total, 122 aneurysms were registered. Their mean maximum diameter and neck length were 6.4 and 3.9 mm, respectively. The mean length of the HydroSoft coils was 84.3%. No intracranial hemorrhage occurred, but 2 patients developed minor ischemic strokes. Angiographic examination immediately after the procedure showed complete obliteration, neck remnant (NR), and body filling (BF) in 20 (16.4%), 32 (26.2%), and 67 (54.9%) cases, respectively. One-year follow-up angiography showed complete obliteration, NR, and BF in 68 (55.7%), 15 (12.3%), and 15 (12.3%) cases, respectively, and 5 aneurysms (4.1%) were recanalized (4 and 1 with BF and NR as their initial angiographic result, respectively). Another 11 aneurysms still showed BF, although their thrombosis was promoted. No significant factors related to recanalization were identified. A high volume embolization ratio and small neck were significantly associated with thrombosis 1 year after embolization with HydroSoft coils.The safety and prevention of recanalization 1 year after the treatment appeared acceptable. The high volume embolization ratio associated with HydroSoft coils could induce progression of thrombosis for aneurysms characterized by NR and BF during the follow-up period.