Back to Search
Start Over
Accuracy of Nasal Nitric Oxide Measurement as a Diagnostic Test for Primary Ciliary Dyskinesia: A Systematic Review and Meta-Analysis
- Source :
- Annals of the American Thoracic Society.
- Publication Year :
- 2017
- Publisher :
- American Thoracic Society, 2017.
-
Abstract
- RATIONALE: Primary ciliary dyskinesia (PCD) is a rare disorder causing chronic otosinopulmonary disease, generally diagnosed through evaluation of respiratory ciliary ultrastructure and/or genetic testing. Nasal nitric oxide (nNO) measurement is used as a PCD screening test because patients with PCD have low nNO levels, but its value as a diagnostic test remains unknown. OBJECTIVES: To perform a systematic review to assess the utility of nNO measurement (index test) as a diagnostic tool compared with the reference standard of electron microscopy (EM) evaluation of ciliary defects and/or detection of biallelic mutations in PCD genes. DATA SOURCES: Ten databases were searched for reference sources from database inception through July 29, 2016. DATA EXTRACTION: Study inclusion was limited to publications with rigorous nNO index testing, reference standard diagnostic testing with EM and/or genetics, and calculable diagnostic accuracy information for cooperative patients (generally >5 yr old) with high suspicion of PCD. SYNTHESIS: Meta-analysis provided a summary estimate for sensitivity and specificity and a hierarchical summary receiver operating characteristic curve. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality, and Grading of Recommendations Assessment, Development, and Evaluation was used to assess the certainty of evidence. In 12 study populations (1,344 patients comprising 514 with PCD and 830 without PCD), using a reference standard of EM alone or EM and/or genetic testing, summary sensitivity was 97.6% (92.7-99.2) and specificity was 96.0% (87.9-98.7), with a positive likelihood ratio of 24.3 (7.6-76.9), a negative likelihood ratio of 0.03 (0.01-0.08), and a diagnostic odds ratio of 956.8 (141.2-6481.5) for nNO measurements. After studies using EM alone as the reference standard were excluded, the seven studies using an extended reference standard of EM and/or genetic testing showed a summary sensitivity of nNO measurements of 96.3% (88.7-98.9) and specificity of 96.4% (85.1-99.2), with a positive likelihood ratio of 26.5 (5.9-119.1), a negative likelihood ratio of 0.04 (0.01-0.12), and a diagnostic odds ratio of 699.3 (67.4-7256.0). Certainty of the evidence was graded as moderate. CONCLUSIONS: nNO is a sensitive and specific test for PCD in cooperative patients (generally >5 yr old) with high clinical suspicion for this disease. With a moderate level of evidence, this meta-analysis confirms that nNO testing using velum closure maneuvers has diagnostic accuracy similar to EM and/or genetic testing for PCD when cystic fibrosis is ruled out. Thus, low nNO values accompanied by an appropriate clinical phenotype could be used as a diagnostic PCD test, though EM and/or genetics will continue to provide confirmatory information.
- Subjects :
- Pulmonary and Respiratory Medicine
medicine.medical_specialty
Pathology
Systematic Reviews
Screening test
Diagnostic accuracy
Nitric Oxide
Sensitivity and Specificity
03 medical and health sciences
0302 clinical medicine
otorhinolaryngologic diseases
medicine
Humans
030212 general & internal medicine
Genetic testing
Primary ciliary dyskinesia
medicine.diagnostic_test
Kartagener Syndrome
business.industry
Diagnostic test
medicine.disease
Nitric Oxide Measurement
Microscopy, Electron
030228 respiratory system
Meta-analysis
Radiology
Ciliary ultrastructure
business
Subjects
Details
- ISSN :
- 23256621 and 23296933
- Database :
- OpenAIRE
- Journal :
- Annals of the American Thoracic Society
- Accession number :
- edsair.doi.dedup.....b91eed65d700123b86187f9db14ddadf
- Full Text :
- https://doi.org/10.1513/annalsats.201701-062sr