Back to Search Start Over

Absorbed dose in the operator’s brain in interventional radiology practices: evaluation through KAP value conversion factors

Authors :
Elena Bakhanova
Frank Becker
Pedro Teles
Isabelle Clairand
Željka Knezevic
Jan Jansen
Paolo Ferrari
Dragana Krstic
Zoran Jovanovic
Sara Principi
ENEA
University of Kragujevac
National Research Center for Radiation Medicine
Geophysical Institute, Karlsruhe Institute of Technology KIT, Hertzstr. 16, 76187 Karlsruhe, Germany
Centre for Radiation, Chemical and Environmental Hazards (CRCE) (PHE)
Biomedical Engineering department, Marquette University
Centro de Ciências e Tecnologias Nucleares (C2TN)
PSE-SANTE/SDOS
Institut de Radioprotection et de Sûreté Nucléaire (IRSN)
Ruđer Bošković Institute (IRB)
Ferrari, P.
Jovanovic, Z.
Bakhanova, E.
Becker, F.
Krstic, D.
Jansen, J.
Principi, S.
Teles, P.
Clairand, I.
Knezevic, Z.
Source :
Physica Medica, Physica Medica, Elsevier, 2020, pp.177-181. ⟨10.1016/j.ejmp.2020.07.011⟩
Publication Year :
2020

Abstract

International audience; In order to address the recent concerns over a possible increasing in brain tumour mortality among interventional radiologists and cardiologist, this work evaluated the exposure conditions of the operator’s brain during interventional procedures using Monte Carlo simulations with anthropomorphic phantoms. The absorbed doses in several predefined segments of the operator’s brain were estimated in a typical interventional radiology irradiation scenario. The doses were normalized to the KAP values simulated for ten X-ray beam qualities and four projections (PA, RAO 25°, LAO 25° and CRA 25°). For the interventional radiology scenario, because of the position of the operator, no difference was found in the exposure between the left and right regions of the brain for the first operator, while for the second operator standing at a farer distance from the tube, the exposure of the left part of the brain is up to two times higher than that of the right part. The results are in agreement with dose measurements reported in the literature. The conversion factors, obtained as the absorbed dose per KAP, can be used to obtain a first estimate of the exposure of the brain of the operators during interventional procedures

Details

Language :
English
ISSN :
11201797
Database :
OpenAIRE
Journal :
Physica Medica, Physica Medica, Elsevier, 2020, pp.177-181. ⟨10.1016/j.ejmp.2020.07.011⟩
Accession number :
edsair.doi.dedup.....b88f09c1c14c925372a66126c1c4f54f