Back to Search Start Over

Respiratory Drive in Patients with Sepsis and Septic Shock: Modulation by High-flow Nasal Cannula

Authors :
Eugenio Garofalo
Elena Spinelli
Bertrand Pavlovsky
Savino Spadaro
Irene Ottaviani
Annalisa Rundo
Domenico Luca Grieco
Tommaso Mauri
Gabriele Pintaudi
Carlo Alberto Volta
Antonio Pesenti
Maria Cristina Basile
Francesca Dalla Corte
Source :
Anesthesiology. 135(6)
Publication Year :
2021

Abstract

Background Experimental and pilot clinical data suggest that spontaneously breathing patients with sepsis and septic shock may present increased respiratory drive and effort, even in the absence of pulmonary infection. The study hypothesis was that respiratory drive and effort may be increased in septic patients and correlated with extrapulmonary determinant and that high-flow nasal cannula may modulate drive and effort. Methods Twenty-five nonintubated patients with extrapulmonary sepsis or septic shock were enrolled. Each patient underwent three consecutive steps: low-flow oxygen at baseline, high-flow nasal cannula, and then low-flow oxygen again. Arterial blood gases, esophageal pressure, and electrical impedance tomography data were recorded toward the end of each step. Respiratory effort was measured as the negative swing of esophageal pressure (ΔPes); drive was quantified as the change in esophageal pressure during the first 500 ms from start of inspiration (P0.5). Dynamic lung compliance was calculated as the tidal volume measured by electrical impedance tomography, divided by ΔPes. The results are presented as medians [25th to 75th percentile]. Results Thirteen patients (52%) were in septic shock. The Sequential Organ Failure Assessment score was 5 [4 to 9]. During low-flow oxygen at baseline, respiratory drive and effort were elevated and significantly correlated with arterial lactate (r = 0.46, P = 0.034) and inversely with dynamic lung compliance (r = –0.735, P < 0.001). Noninvasive support by high-flow nasal cannula induced a significant decrease of respiratory drive (P0.5: 6.0 [4.4 to 9.0] vs. 4.3 [3.5 to 6.6] vs. 6.6 [4.9 to 10.7] cm H2O, P < 0.001) and effort (ΔPes: 8.0 [6.0 to 11.5] vs. 5.5 [4.5 to 8.0] vs. 7.5 [6.0 to 12.6] cm H2O, P < 0.001). Oxygenation and arterial carbon dioxide levels remained stable during all study phases. Conclusions Patients with sepsis and septic shock of extrapulmonary origin present elevated respiratory drive and effort, which can be effectively reduced by high-flow nasal cannula. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New

Details

ISSN :
15281175
Volume :
135
Issue :
6
Database :
OpenAIRE
Journal :
Anesthesiology
Accession number :
edsair.doi.dedup.....b88b5efd273985fc2fbe54df2f03fdea