Back to Search
Start Over
Ionic liquids improved reversed-phase HPLC on-line coupled with ICP-MS for selenium speciation
- Source :
- Talanta. 83:724-731
- Publication Year :
- 2011
- Publisher :
- Elsevier BV, 2011.
-
Abstract
- Room-temperature ionic liquids (RTILs) improved reversed-phase high performance liquid chromatography (RP-HPLC) on-line combined with inductively coupled plasma mass spectrometry (ICP-MS) was developed for selenium speciation. The different parameters affecting the retention behaviors of six target selenium species especially the effect of RTILs as mobile phase additives have been studied, it was found that the mobile phase consisting of 0.4% (v/v) 1-butyl-3-methylimidazolium chloride ([BMIM]Cl), 0.4% (v/v) 1-butyl-2,3-dimethylimidazolium tetrafluroborate ([BMMIM]BF(4)) and 99.2% (v/v) water has effectively improved the peak profile and six target selenium species including Na(2)SeO(3) (Se(IV)), Na(2)SeO(4) (Se(VI)), L-selenocystine (SeCys(2)), D,L-selenomethionine (SeMet), Se-methylseleno-l-cysteine (MeSeCys), seleno-D,L-ethionine (SeEt) were separated in 8 min. In order to validate the accuracy of the method, a Certified Reference Material of SELM-1 yeast sample was analyzed and the results obtained were in good agreement with the certified values. The developed method was also successfully applied to the speciation of selenium in Se-enriched yeasts and clover. For fresh Se-enriched yeast cells, it was found that the spiked SeCys(2) in living yeast cells could be transformed into SeMet. Compared with other ion-pair RP-HPLC-ICP-MS approaches for selenium speciation, the proposed method possessed the advantages including ability to regulate the retention time of the target selenium species by selecting the suitable RTILs and their concentration, simplicity, rapidness and low injection volume, thus providing wide potential applications for elemental speciation in biological systems.
- Subjects :
- media_common.quotation_subject
Ionic Liquids
chemistry.chemical_element
Online Systems
High-performance liquid chromatography
Chloride
Mass Spectrometry
Analytical Chemistry
Selenium
chemistry.chemical_compound
Yeasts
Medicago
medicine
Selenium Compounds
Inductively coupled plasma mass spectrometry
Biotransformation
Chromatography, High Pressure Liquid
media_common
Chromatography, Reverse-Phase
Chromatography
Chemistry
Methanol
Imidazoles
Temperature
Reproducibility of Results
Reversed-phase chromatography
Hydrogen-Ion Concentration
Reference Standards
Kinetics
Speciation
Certified reference materials
Ionic liquid
Indicators and Reagents
medicine.drug
Subjects
Details
- ISSN :
- 00399140
- Volume :
- 83
- Database :
- OpenAIRE
- Journal :
- Talanta
- Accession number :
- edsair.doi.dedup.....b7fa0fa9e2a11c68ea85b441cc9dae26