Back to Search
Start Over
Outcomes of balloon-expandable versus self-expandable stent graft for endovascular repair of iliac aneurysms using iliac branch endoprosthesis
- Source :
- European Journal of Vascular and Endovascular Surgery. 63:e80-e81
- Publication Year :
- 2022
- Publisher :
- Elsevier BV, 2022.
-
Abstract
- PURPOSE The purpose of this study was to compare outcomes of internal iliac artery (IIA) stenting using balloon-expandable (BESG) or self-expandable stent grafts (SESG) during endovascular repair of aortoiliac aneurysms with iliac branch endoprosthesis (IBE; W. L. Gore, Flagstaff, Ariz). METHODS We retrospectively reviewed all consecutive patients treated for aortoiliac aneurysms using IBE between 2014 and 2020. IIA stenting was performed using either the IIA side branch SESG or a Gore VBX BESG (W. L. Gore). Indications for use of BESGs were "up-and-over" IBE technique for type IB endoleak after prior endovascular aortic aneurysm repair (EVAR), short IIA length, and need for IIA extension into divisional branches (outside instructions for use). End points included technical success, freedom from buttock claudication, primary IIA patency, and freedom from IIA branch instability (eg, branch-related death or rupture, occlusion, disconnection, or reintervention for stenosis, kink, or endoleak), freedom from type IC/IIIC endoleak, and freedom from secondary interventions. RESULTS There were 90 patients (86 males and 4 females) with a mean age of 74 ± 7 years treated by EVAR with 108 IBEs. Choice of stent was BESG in 43 and SESG in 65 targeted IIAs. BESGs were used more frequently in patients with prior EVAR (22% vs 2%; P = .003,), isolated IBEs (31% vs 2%; P < .001), and in patients with IIA aneurysms requiring stenting into divisional branches (36% vs 5%; P < .001). Technical success was similar for BESGs and SESGs (97% vs 100%; P = .40), respectively. The mean follow-up was 25 ± 16 months (range, 11-34 months). At 2 years, freedom from buttock claudication was 100% for BESG and 95 ± 3% for SESG (Log-rank 0.26), with no difference in primary patency (BESG, 100% vs SESG, 94 ± 4%; Log-rank 0.94). There were four (9%) IIA-related endoleaks in the BESG group and one (2%) in the SESG group (P = .08). Freedom from IIA branch instability was 87 ± 6% for BESG and 96 ± 3% for SESG at 2 years (Log-rank 0.043). Freedom from type IC/IIIC endoleak was 87 ± 7% for BESG and 98 ± 2% for SESG at the same interval (Log-rank 0.06). There was no difference in freedom from reinterventions for BESG and SESG (92 ± 6% vs 98 ± 2%; Log-rank 0.34), respectively. CONCLUSIONS BESGs were used more frequently during IBE procedures indicated for failed EVAR, isolated common iliac aneurysms, and IIA aneurysms requiring extension into divisional branches. Despite these differences and BESG being used outside instructions for use, both stent types had similar primary patency, freedom from buttock claudication, and freedom from reinterventions. However, BESGs were associated with higher rates of IIA-related branch instability.
- Subjects :
- Male
medicine.medical_specialty
Time Factors
Endoleak
medicine.medical_treatment
Prosthesis Design
Blood Vessel Prosthesis Implantation
Risk Factors
Side branch
medicine.artery
Occlusion
medicine
Humans
Iliac Aneurysm
Vascular Patency
Aged
Retrospective Studies
Aged, 80 and over
business.industry
Self expandable
Endovascular Procedures
Stent
Intermittent Claudication
medicine.disease
Internal iliac artery
Surgery
Blood Vessel Prosthesis
Stenosis
Balloon expandable stent
Treatment Outcome
Female
Stents
business
Cardiology and Cardiovascular Medicine
Subjects
Details
- ISSN :
- 10785884
- Volume :
- 63
- Database :
- OpenAIRE
- Journal :
- European Journal of Vascular and Endovascular Surgery
- Accession number :
- edsair.doi.dedup.....b7da56df2f0230d69742cc5ac201dc65