Back to Search
Start Over
Development and application of a motion analysis protocol for the kinematic evaluation of basic and functional hand and finger movements using motion capture in a clinical setting-A repeatability study
- Source :
- Applied Sciences, 10 (18), Applied Sciences, Vol 10, Iss 6436, p 6436 (2020), Applied Sciences, Volume 10, Issue 18
- Publication Year :
- 2020
- Publisher :
- MDPI, 2020.
-
Abstract
- The purpose of this study was to develop a motion analysis protocol that allows the simultaneous assessment of all hand and finger joint movements. The objective was to demonstrate repeatability for future clinical applications in functional assessments. This study includes selection of marker positions, movement tasks, kinematic approaches and a comparison of the two most commonly used finger marker sets. By using a test&ndash<br />retest measurement of the range of motion in twenty healthy volunteers, the repeatability of the developed protocol was validated. Estimated errors of the presented method ranged from 1.2&deg<br />to 6.4&deg<br />Finger joint angles derived from the marker set with two markers per segment showed better repeatability (3.7&deg<br />) than with markers located on the joints (5.1&deg<br />). Given the high repeatability found, the presented method appears to be suitable for clinical applications. For the fingers, measurement repeatability can be improved by using at least two markers per segment. Within this study, advanced kinematic approaches, such as functional determination of joint centers and axes, are applied to the analysis of hand movements. The provided standard values and estimate of the minimal detectable differences provide a valuable basis for meaningful data interpretation and may be used for future comparison with other protocols.
- Subjects :
- functional joint coordinate system
minimal detectable difference
610 Medicine & health
lcsh:Technology
range of motion
lcsh:Chemistry
1706 Computer Science Applications
motion capture
repeatability
10266 Clinic for Reconstructive Surgery
lcsh:QH301-705.5
lcsh:T
3105 Instrumentation
1507 Fluid Flow and Transfer Processes
finger kinematics
hand kinematics
motion analysis protocol
2500 General Materials Science
lcsh:QC1-999
lcsh:Biology (General)
lcsh:QD1-999
lcsh:TA1-2040
2200 General Engineering
1508 Process Chemistry and Technology
lcsh:Engineering (General). Civil engineering (General)
lcsh:Physics
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Applied Sciences, 10 (18), Applied Sciences, Vol 10, Iss 6436, p 6436 (2020), Applied Sciences, Volume 10, Issue 18
- Accession number :
- edsair.doi.dedup.....b7c5c11e1bafd3b6a68d4222fa19ee3a