Back to Search Start Over

Critical assessment of automated flow cytometry data analysis techniques

Authors :
Aghaeepour, N
Finak, G
Flowcap, Consortium
Dougall, D
Khodabakhshi, Ah
Mah, P
Obermoser, G
Spidlen, J
Taylor, I
Wuensch, Sa
Bramson, J
Eaves, C
Weng, Ap
Iii, Es
Ho, K
Kollmann, T
Rogers, W
De Rosa, S
Dalal, B
Azad, A
Pothen, A
Brandes, A
Bretschneider, H
Bruggner, R
Finck, R
Jia, R
Zimmerman, N
Linderman, M
Dill, D
Nolan, G
Chan, C
Khettabi, Fe
O'Neill, K
Chikina, M
Ge, Y
Sealfon, S
Sugár, I
Gupta, A
Shooshtari, P
Zare, H
De Jager PL
Jiang, M
Keilwagen, J
Maisog, Jm
Luta, G
Barbo, Aa
Májek, P
Vilček, J
Manninen, T
Huttunen, H
Ruusuvuori, P
Nykter, M
Mclachlan, Gj
Wang, K
Naim, I
Sharma, G
Nikolic, R
Pyne, S
Qian, Y
Qiu, P
Quinn, J
Roth, A
Dream, Consortium
Meyer, P
Stolovitzky, G
Saez Rodriguez, J
Norel, R
Bhattacharjee, M
Biehl, M
Bucher, P
Bunte, K
DI CAMILLO, Barbara
Sambo, Francesco
Sanavia, Tiziana
Trifoglio, Emanuele
Toffolo, GIANNA MARIA
Dimitrieva, S
Dreos, R
Ambrosini, G
Grau, J
Grosse, I
Posch, S
Guex, N
Kursa, M
Rudnicki, W
Liu, B
Maienschein Cline, M
Schneider, P
Seifert, M
Strickert, M
Vilar, Jm
Hoos, H
Mosmann, Tr
Brinkman, R
Gottardo, R
Scheuermann, Rh
Dialogue for Reverse Engineering Assessment and Methods (DREAM) Consortium
Guex, Nicolas
Abrosini, Giovanna
Source :
Nature methods, Nature Methods, vol. 10, no. 3, pp. 228-238
Publication Year :
2013

Abstract

Traditional methods for flow cytometry (FCM) data processing rely on subjective manual gating. Recently, several groups have developed computational methods for identifying cell populations in multidimensional FCM data. The Flow Cytometry: Critical Assessment of Population Identification Methods (FlowCAP) challenges were established to compare the performance of these methods on two tasks: (i) mammalian cell population identification, to determine whether automated algorithms can reproduce expert manual gating and (ii) sample classification, to determine whether analysis pipelines can identify characteristics that correlate with external variables (such as clinical outcome). This analysis presents the results of the first FlowCAP challenges. Several methods performed well as compared to manual gating or external variables using statistical performance measures, which suggests that automated methods have reached a sufficient level of maturity and accuracy for reliable use in FCM data analysis.

Details

Language :
English
Database :
OpenAIRE
Journal :
Nature methods, Nature Methods, vol. 10, no. 3, pp. 228-238
Accession number :
edsair.doi.dedup.....b7ba010694f623c40214d04737abc900