Back to Search Start Over

Echo rejection score: new echocardiographic approach to diagnosis of heart transplant rejection☆

Authors :
Mohammad Hossein Mandegar
Farshid Alaeddini
Farideh Roshanali
Bahare Saidi
Sam Chitsaz
Mahmood Reza Sarzaeem
Jamshid Bagheri
Source :
European Journal of Cardio-Thoracic Surgery. 38:176-180
Publication Year :
2010
Publisher :
Oxford University Press (OUP), 2010.

Abstract

Objective: The gold standard test in the diagnosis of heart transplant rejection is right ventricular (RV) myocardial biopsy, which is an invasive, time-consuming, expensive method. In an effort to find a reliable method to minimise the sequential use of myocardial biopsy, we assessed the main echocardiographic indices for the detection of allograft rejection. Materials and methods: Fifty myocardial specimens were examined in this prospective study, which assessed the prominent echocardiographic parameters propounded by previous studies as indicators of rejection. Prior to biopsy, all the patients underwent preoperative transthoracic echocardiography. The accuracy of the echocardiographic indices was compared with that of myocardial biopsy indices as the gold standard. At three myocardial segments, namely, RV base, interventricular septal (Sep) base and lateral left ventricular (Lat) base, peak systolic strain (RV-S, Lat-S and Sep-S) was measured. In addition, time to systole (TS) was measured at the same three segments, yielding the three variables of RV-TS, Sep-TS and Lat-TS. Results: Our logistic regression model revealed that the four factors of Lat-S (%), Sep-TS (ms), posterior wall thickness (PWT; mm) and left ventricular mass index (LVMI; g m � 2 ) could denote hearttransplantrejection.Wedeviseda newindex,theechorejectionscore,usingthefollowingformula: [(PWT + LVMI) � (Lat-S + Sep-TS)].This new formula has an area under a curve of 0.932 and a cut-off point of 0; it yields a sensitivity of 100.0%, specificity of 71.0%, positive predictive value of 67.9% and a negative predictive value of 100.0%. If the echo rejection score is >0, there is a 67.9% possibility that a cardiac transplant patient is presenting with allograft rejection, while a score � 0 denotes a 100% improbability of rejection. Conclusion: Our proposed method for screening patients at risk of acute cardiac rejection with echo rejection score showed a good sensitivity in detection of graft rejection. However, further study is required to determine if it can be used as an adjunct to the myocardial biopsy. # 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

Details

ISSN :
10107940
Volume :
38
Database :
OpenAIRE
Journal :
European Journal of Cardio-Thoracic Surgery
Accession number :
edsair.doi.dedup.....b75ccbf2737af52cbd8c50a3ff2faf19