Back to Search
Start Over
C-Met targeted fluorescence molecular endoscopy in Barrett's esophagus patients and identification of outcome parameters for phase-I studies
- Source :
- Theranostics, 10(12), 5357-5367. Ivyspring International Publisher, Theranostics, 10(12), 5357-5367. IVYSPRING INT PUBL, Theranostics
- Publication Year :
- 2020
-
Abstract
- Fluorescence molecular endoscopy (FME) is an emerging technique in the field of gastroenterology that holds potential to improve diagnosis and guide therapy, by serving as a 'red-flag' endoscopic imaging technique. Here, we investigated the safety, feasibility and optimal method of administration of EMI-137, targeting c-Met, during FME in Barrett's Esophagus (BE) and report several outcome parameters for early phase FME studies. Methods: FME was performed in 15 Barrett's neoplasia patients. EMI-137 was administered to three cohorts of five patients: 0.13 mg/kg intravenously (IV); 0.09 mg/kg IV or topically at a dose of 200 μg/cm BE (n=1) or 100 μg/cm BE (n=4). Fluorescence was visualized in vivo, quantified in vivo using multi-diameter single-fiber reflectance, single-fiber fluorescence (MDSFR/SFF) spectroscopy and correlated to histopathology and immunohistochemistry. EMI-137 localization was assessed using fluorescence microscopy. Results: FME using different IV and topical doses of EMI-137 appeared to be safe and correctly identified 16/18 lesions, although modest target-to-background ratios were observed (median range of 1.12-1.50). C-Met overexpression varied between lesions, while physiological expression in the stomach-type epithelium was observed. Microscopically, EMI-137 accumulated around the neoplastic cell membranes. We identified several outcome parameters important for the validation of EMI-137 for FME: 1) the optimal administration route; 2) optimal dose and safety; 3) in vivo FME contrast; 4) quantification of intrinsic fluorescence; 5) ex vivo correlation of fluorescence, histopathology and target expression; and 6) microscopic tracer distribution. Conclusions: C-Met targeted FME using EMI-137 may not be the ideal combination to improve BE surveillance endoscopies, however the identified outcome parameters may serve as a valuable guidance for designing and performing future early phase clinical FME studies, independent of which fluorescent tracer is investigated.
- Subjects :
- 0301 basic medicine
Male
medicine.medical_specialty
Esophageal Neoplasms
IMAGING AGENTS
Biopsy
Medicine (miscellaneous)
EMI-137 targeting c-Met
03 medical and health sciences
Barrett Esophagus
Barrett's esophagus
0302 clinical medicine
In vivo
ADENOMAS
medicine
Fluorescence microscope
Humans
Prospective Studies
Esophagus
Pharmacology, Toxicology and Pharmaceutics (miscellaneous)
Aged
business.industry
standardized fluorescence molecular endoscopy methodology
Middle Aged
Proto-Oncogene Proteins c-met
medicine.disease
CANCER
Structured roadmap
030104 developmental biology
medicine.anatomical_structure
Immunohistochemistry
Neoplastic cell
030211 gastroenterology & hepatology
Histopathology
Female
Nuclear medicine
business
Ex vivo
Research Paper
Subjects
Details
- Language :
- English
- ISSN :
- 18387640
- Volume :
- 10
- Issue :
- 12
- Database :
- OpenAIRE
- Journal :
- Theranostics
- Accession number :
- edsair.doi.dedup.....b73fe6acc0242a92d7cc860342e08253