Back to Search
Start Over
Human Lacrimal Production Rate and Wetted Length of Modified Schirmer's Tear Test Strips
- Source :
- Translational Vision Science & Technology, Translational vision science & technology, vol 8, iss 3
- Publication Year :
- 2018
-
Abstract
- Author(s): Kim, Young Hyun; Graham, Andrew D; Li, Wing; Radke, Clayton J; Lin, Meng C | Abstract: PurposeTo assess and compare the wetting kinetics of sheathed and unsheathed Schirmer's tear test (STT) strips, and to determine the repeatability of 5-minute wetted length (WL) and basal tear production rate (BTPR).MethodsSeventeen subjects underwent two sheathed and unsheathed STTs each for both eyes on four visits on separate days. After administration of topical anesthetic, WLs were measured every 30 seconds for 5 minutes, and BTPRs were calculated for sheathed strips. Limits of agreement (LoA), difference-versus-mean plots (DVM), and the coefficient of repeatability (CR) assessed WL and BTPR repeatabilities. Variance estimates were used to calculate sample sizes for future study.ResultsFor the unsheathed STT, the mean (SD) difference in WLs between visits was 0.74 (5.05) mm, LoA were [-9.17, 10.64], and CR was 9.17 mm; for the sheathed STT, the mean (SD) intervisit difference was 0.16 (5.94) mm, LoA were [-11.49, 11.8], and CR was 10.53 mm. Eight of 48 sheathed STTs and 20 of 44 unsheathed STTs showed constant WL for the final 90 seconds of the test. The mean (SD) difference between repeated visits for BTPR was approximately 0.0 μL/min, LoA were [-1.82, 1.82], and CR was 1.91 μL/min.ConclusionsRepeatability of sheathed and unsheathed 5-minute WL and BTPR is inadequate for measuring within-subject changes, but is sufficient for group studies with moderate sample sizes. Constant WL for the final 90 seconds with the eight sheathed STT measurements suggests varying BTPR, whereas constant WL with the unsheathed STT can be explained by balancing evaporation and BTPR.Translational relevanceRepeatability of the modified STT is evaluated clinically to establish quantitative BTPRs rather than inference from a strip WL.
- Subjects :
- 0301 basic medicine
Materials science
modified Schirmer's tear test
Biomedical Engineering
Tear production
Test strips
03 medical and health sciences
dry eye
0302 clinical medicine
Clinical Research
Opthalmology and Optometry
repeatability
tear production rate
wetted length
Schirmer strip
sample size estimation
business.industry
Limits of agreement
Repeatability
Articles
Ophthalmology
030104 developmental biology
030221 ophthalmology & optometry
Nuclear medicine
business
Production rate
Subjects
Details
- ISSN :
- 21642591
- Volume :
- 8
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Translational vision sciencetechnology
- Accession number :
- edsair.doi.dedup.....b72a148df9e352712455209db3488007