Back to Search Start Over

Automated 3D Sampling and Imaging of Uneven Sample Surfaces with LA-REIMS

Authors :
Sylvia P. Nauta
Pascal Huysmans
Gabriƫlle J. M. Tuijthof
Gert B. Eijkel
Martijn Poeze
Tiffany Porta Siegel
Ron M. A. Heeren
Orthopedic Surgery and Sports Medicine
AMS - Amsterdam Movement Sciences
AMS - Rehabilitation & Development
RS: M4I - Imaging Mass Spectrometry (IMS)
M4I
IDEE (Instrument Develop Engin & Eval)
Surgery
MUMC+: MA Heelkunde (9)
MUMC+: NAZL en ROAZ (9)
RS: NUTRIM - R3 - Respiratory & Age-related Health
Imaging Mass Spectrometry (IMS)
Source :
Journal of the American Society for Mass Spectrometry, Journal of the American Society for Mass Spectrometry, 33(1), 111-122. Springer New York, Journal of the American Society for Mass Spectrometry, 33(1), 111-122. Springer, Cham
Publication Year :
2021
Publisher :
American Chemical Society, 2021.

Abstract

The analysis of samples with large height variations remains a challenge for mass spectrometry imaging (MSI), despite many technological advantages. Ambient sampling and ionization MS techniques allow for the molecular analysis of sample surfaces with height variations, but most techniques lack MSI capabilities. We developed a 3D MS scanner for the automated sampling and imaging of a 3D surface with laser-assisted rapid evaporative ionization mass spectrometry (LA-REIMS). The sample is moved automatically with a constant distance between the laser probe and sample surface in the 3D MS Scanner. The topography of the surface was scanned with a laser point distance sensor to define the MS measurement points. MS acquisition was performed with LA-REIMS using a surgical CO2 laser coupled to a qTOF instrument. The topographical scan and MS acquisition can be completed within 1 h using the 3D MS scanner for 300 measurement points on uneven samples with a spatial resolution of 2 mm in the top view, corresponding to 22.04 cm(2). Comparison between the automated acquisition with the 3D MS scanner and manual acquisition by hand showed that the automation resulted in increased reproducibility between the measurement points. 3D visualizations of molecular distributions related to structural differences were shown for an apple, a marrowbone, and a human femoral head to demonstrate the imaging feasibility of the system. The developed 3D MS scanner allows for the automated sampling of surfaces with uneven topographies with LA-REIMS, which can be used for the 3D visualization of molecular distributions of these surfaces.

Details

Language :
English
ISSN :
18791123 and 10440305
Volume :
33
Issue :
1
Database :
OpenAIRE
Journal :
Journal of the American Society for Mass Spectrometry
Accession number :
edsair.doi.dedup.....b71031331d3fd764d6a6b0f4e16d3e0c