Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study
- Source :
- Journal of vascular and interventional radiology : JVIR. 15(4)
- Publication Year :
- 2004
-
Abstract
- PURPOSE To evaluate and compare visibility and artifacts in magnetic resonance (MR) compatible radiofrequency (RF) electrodes for MR-guided RF ablation. MATERIAL AND METHODS Six different MR compatible electrodes for RF ablation including two internally cooled single needles, one internally cooled cluster needle, two expandable needles and one perfused needle were tested in a phantom study at 0.2 Tesla and at 1.5 Tesla field strength. Fluoroscopic, T1and T2-weighted fast spin echo (FSE) and gradient echo (GE) sequences, which are usually used for MR-guided interventions, were evaluated. Qualitative and quantitative evaluations were performed. Length, width, noise, tip artifacts, global artifacts and global visualization of the RF electrodes that showed all sequences at different angles. RESULTS Qualitative analysis showed that electrodes were well visualized at all angles and sequences and on both MR imagers. Quantitative analysis showed that artifact-induced widening of the shaft was increased in all electrodes by: a) use of fluoroscopic sequences, GE sequences, and fat saturation, b) increasing the angle between the needle and main magnetic field, and c) high field strength (1.5 T). Expandable needles produced fewer tip artifacts but broader signal voids along the shaft compared to nonexpandable needles. Cluster electrodes produced less widening than the other electrodes. CONCLUSION Visibility and artifacts in all six MR compatible RF electrodes are satisfactory and these electrodes could be used for MR-guided radiofrequency ablation procedures.
- Subjects :
- Radiofrequency ablation
Field strength
Signal
Noise (electronics)
Imaging phantom
law.invention
Nuclear magnetic resonance
law
Image Processing, Computer-Assisted
Medicine
Humans
Radiology, Nuclear Medicine and imaging
medicine.diagnostic_test
business.industry
Phantoms, Imaging
Magnetic resonance imaging
Equipment Design
Magnetic Resonance Imaging
Magnetic field
Electrodes, Implanted
Perfusion
Treatment Outcome
Needles
Electrode
Catheter Ablation
Cardiology and Cardiovascular Medicine
business
Artifacts
Subjects
Details
- ISSN :
- 10510443
- Volume :
- 15
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Journal of vascular and interventional radiology : JVIR
- Accession number :
- edsair.doi.dedup.....b6d707b5b581861520931d55befb234a