Back to Search
Start Over
A novel depth estimation algorithm of chest compression for feedback of high-quality cardiopulmonary resuscitation based on a smartwatch
- Source :
- Journal of biomedical informatics. 87
- Publication Year :
- 2018
-
Abstract
- Introduction High-quality cardiopulmonary resuscitation (CPR) is a key factor affecting cardiac arrest survival. Accurate monitoring and real-time feedback are emphasized to improve CPR quality. The purpose of this study was to develop and validate a novel depth estimation algorithm based on a smartwatch equipped with a built-in accelerometer for feedback instructions during CPR. Methods For data collection and model building, researchers wore an Android Wear smartwatch and performed chest compression-only CPR on a Resusci Anne QCPR training manikin. We developed an algorithm based on the assumptions that (1) maximal acceleration measured by the smartwatch accelerometer and the chest compression depth (CCD) are positively correlated and (2) the magnitude of acceleration at a specific time point and interval is correlated with its neighboring points. We defined a statistic value M as a function of time and the magnitude of maximal acceleration. We labeled and processed collected data and determined the relationship between M value, compression rate and CCD. We built a model accordingly, and developed a smartwatch app capable of detecting CCD. For validation, researchers wore a smartwatch with the preinstalled app and performed chest compression-only CPR on the manikin at target sessions. We compared the CCD results given by the smartwatch and the reference using the Wilcoxon Signed Rank Test (WSRT), and used Bland-Altman (BA) analysis to assess the agreement between the two methods. Results We analyzed a total of 3978 compressions that covered the target rate of 80–140/min and CCD of 4–7 cm. WSRT showed that there was no significant difference between the two methods (P = 0.084). By BA analysis the mean of differences was 0.003 and the bias between the two methods was not significant (95% CI: −0.079 to 0.085). Conclusion Our study indicates that the algorithm developed for estimating CCD based on a smartwatch with a built-in accelerometer is promising. Further studies will be conducted to evaluate its application for CPR training and clinical practice.
- Subjects :
- Wilcoxon signed-rank test
Computer science
medicine.medical_treatment
Acceleration
Monitoring, Ambulatory
Health Informatics
030204 cardiovascular system & hematology
Accelerometer
Manikins
Feedback
Workflow
Smartwatch
03 medical and health sciences
Wearable Electronic Devices
0302 clinical medicine
Android Wear
medicine
Humans
Cardiopulmonary resuscitation
Data collection
Models, Statistical
Reproducibility of Results
030208 emergency & critical care medicine
Data compression ratio
Reference Standards
Mobile Applications
Cardiopulmonary Resuscitation
Computer Science Applications
Heart Arrest
Algorithm
Algorithms
Software
Subjects
Details
- ISSN :
- 15320480
- Volume :
- 87
- Database :
- OpenAIRE
- Journal :
- Journal of biomedical informatics
- Accession number :