Back to Search
Start Over
Personal Exposure Estimates via Portable and Wireless Sensing and Reporting of Particulate Pollution
- Source :
- International Journal of Environmental Research and Public Health, International Journal of Environmental Research and Public Health, Vol 17, Iss 3, p 843 (2020), Volume 17, Issue 3
- Publication Year :
- 2020
- Publisher :
- MDPI, 2020.
-
Abstract
- Low-cost, portable particle sensors (n = 3) were designed, constructed, and used to monitor human exposure to particle pollution at various locations and times in Lubbock, TX. The air sensors consisted of a Sharp GP2Y1010AU0F dust sensor interfaced to an Arduino Uno R3, and a FONA808 3G communications module. The Arduino Uno was used to receive the signal from calibrated dust sensors to provide a concentration (&micro<br />g/m3) of suspended particulate matter and coordinate wireless transmission of data via the 3G cellular network. Prior to use for monitoring, dust sensors were calibrated against a reference aerosol monitor (RAM-1) operating independently. Sodium chloride particles were generated inside of a 3.6 m3 mixing chamber while the RAM-1 and each dust sensor recorded signals and calibration was achieved for each dust sensor independently of others by direct comparison with the RAM-1 reading. In an effort to improve the quality of the data stream, the effect of averaging replicate individual pulses of the Sharp sensor when analyzing zero air has been studied. Averaging data points exponentially reduces standard deviation for all sensors with n &lt<br />2000 averages but averaging produced diminishing returns after approx. 2000 averages. The sensors exhibited standard deviations for replicate measurements of 3&ndash<br />6 &micro<br />g/m3 and corresponding 3 detection limits of 9&ndash<br />18 &micro<br />g/m3 when 2000 pulses of the dust sensor LED were averaged over an approx. 2 minute data collection/transmission cycle. To demonstrate portable monitoring, concentration values from the dust sensors were sent wirelessly in real time to a ThingSpeak channel, while tracking the sensor&rsquo<br />s latitude and longitude using an on-board Global Positioning System (GPS) sensor. Outdoor and indoor air quality measurements were made at different places and times while human volunteers carried sensors. The measurements indicated walking by restaurants and cooking at home increased the exposure to particulate matter. The construction of the dust sensors and data collected from this research enhance the current research by describing an open-source concept and providing initial measurements. In principle, sensors can be massively multiplexed and used to generate real-time maps of particulate matter around a given location.
- Subjects :
- wireless networks
IoT
010504 meteorology & atmospheric sciences
Health, Toxicology and Mutagenesis
lcsh:Medicine
human exposure
010501 environmental sciences
01 natural sciences
Signal
Article
crowd-sensing
Indoor air quality
dust sensor
Calibration
pollution
Arduino
Humans
Particle Size
Air quality index
0105 earth and related environmental sciences
Remote sensing
particulate matter
Air Pollutants
business.industry
Particulate pollution
lcsh:R
Public Health, Environmental and Occupational Health
Dust
Environmental Exposure
Particulates
air quality
Texas
Aerosol
environmental analysis
Global Positioning System
crowd-sourced sensing
Environmental science
business
Wireless Technology
Environmental Monitoring
Subjects
Details
- Language :
- English
- ISSN :
- 16604601 and 16617827
- Volume :
- 17
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- International Journal of Environmental Research and Public Health
- Accession number :
- edsair.doi.dedup.....b601679b61e45849d16aab59ee53239b