Back to Search
Start Over
Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts
- Source :
- IEEE Transactions on Medical Imaging. 29:1676-1687
- Publication Year :
- 2010
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2010.
-
Abstract
- The shape of the mitral valve annulus is used in diagnostic and modeling applications, yet methods to accurately and reproducibly delineate the annulus are limited. This paper presents a mitral annulus segmentation algorithm designed for closed mitral valves which locates the annulus in three-dimensional ultrasound using only a single user-specified point near the center of the valve. The algorithm first constructs a surface at the location of the thin leaflets, and then locates the annulus by finding where the thin leaflet tissue meets the thicker heart wall. The algorithm iterates until convergence metrics are satisfied, resulting in an operator-independent mitral annulus segmentation. The accuracy of the algorithm was assessed from both a diagnostic and surgical standpoint by comparing the algorithm's results to delineations made by a group of experts on clinical ultrasound images of the mitral valve, and to delineations made by an expert with a surgical view of the mitral annulus on excised porcine hearts using an electromagnetically tracked pointer. In the former study, the algorithm was statistically indistinguishable from the best performing expert (p=0.85) and had an average RMS difference of 1.81+/-0.78 mm to the expert average. In the latter, the average RMS difference between the algorithm's annulus and the electromagnetically tracked points across six hearts was 1.19+/-0.17 mm .
- Subjects :
- Swine
Computer science
Echocardiography, Three-Dimensional
Article
Cut
Mitral valve
Image Processing, Computer-Assisted
medicine
Animals
Humans
Mitral Valve Annulus
3D ultrasound
Segmentation
cardiovascular diseases
Mitral annulus
Electrical and Electronic Engineering
Radiological and Ultrasound Technology
medicine.diagnostic_test
business.industry
Ultrasound
Models, Cardiovascular
Reproducibility of Results
Annulus (mathematics)
Heart wall
Image segmentation
Anatomy
musculoskeletal system
Computer Science Applications
medicine.anatomical_structure
cardiovascular system
Mitral Valve
business
Algorithms
Software
Biomedical engineering
Subjects
Details
- ISSN :
- 1558254X and 02780062
- Volume :
- 29
- Database :
- OpenAIRE
- Journal :
- IEEE Transactions on Medical Imaging
- Accession number :
- edsair.doi.dedup.....b5e788bee7708d5a8e488cfa1e30b760