Back to Search Start Over

Laser and beta source setup characterization of 3D-DDTC detectors fabricated at FBK-irst

Authors :
A. Zoboli
L. Bosisio
Maurizio Boscardin
Claudio Piemonte
S. Eckert
Ulrich Parzefall
S. Kühn
G.-F. Dalla Betta
Sabina Ronchin
Nicola Zorzi
A., Zoboli
G. F., Dalla Betta
M., Boscardin
Bosisio, Luciano
S., Eckert
S., Kuhn
U., Parzefall
C., Piemonte
S., Ronchin
N., Zorzi
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 604:238-241
Publication Year :
2009
Publisher :
Elsevier BV, 2009.

Abstract

We report on the functional characterization of the first batch of 3D Double-Sided Double Type Column (3D-DDTC) detectors fabricated at FBK, Trento. This detector concept represents the evolution of the previous 3D-STC detectors towards full 3D detectors, and is expected to achieve a performance which is comparable to standard 3D detectors, but with a simpler fabrication process. Measurements were performed on detectors in the microstrip configuration coupled to the ATLAS ABCD3T binary readout. This paper reports spatially resolved signal efficiency tests made with a pulsed infrared laser setup and charge collection efficiency tests made with a Beta source.

Details

ISSN :
01689002
Volume :
604
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi.dedup.....b5938e4b3a89ed6979ffa816c1df9cd2
Full Text :
https://doi.org/10.1016/j.nima.2009.01.073