Back to Search Start Over

Do collagen cross-linkers improve dentin’s bonding receptiveness?

Do collagen cross-linkers improve dentin’s bonding receptiveness?

Authors :
J. De Munck
Guilherme Carpena Lopes
Ana Paula Almeida Ayres
C. Parise Gré
R. Seseogullari-Dirihan
Arzu Tezvergil-Mutluay
K.L. Van Landuyt
Bart Van Meerbeek
D. Pedrollo Lise
Source :
Dental Materials. 34:1679-1689
Publication Year :
2018
Publisher :
Elsevier BV, 2018.

Abstract

Dentin biomodification using collagen cross-linkers has been proposed as one of the strategies to improve bond durability of adhesives to dentin. However, literature is not very consistent regarding their benefit, in particular when cross-linkers are applied in clinically realistic application times. This study investigated the effect of three cross-linkers on the mini-interfacial fracture toughness (mini-iFT) of four adhesives bonded to dentin following either etchrinse (ER) or self-etch (SE) modes.60 molars were randomly divided in accordance with the three variables: cross-linker, adhesive and bonding mode (n=5). The cross-linkers glutaraldehyde (5wt%; GA), proanthocyanidin (6.5wt%; PA), or UVA-activated riboflavin (0.5wt%; RB), and distilled water (control) were applied on dentin for 60s after acid-etching (ER) or before self-etching (SE). The 3-step ER adhesive (3ERa) OptiBond FL (Kerr), the 2-step SE adhesive (2SEa) Clearfil SE Bond 2 (Kuraray Noritake) and the universal adhesives G-Premio Bond (GC) and PrimeBond Active (Dentsply), the latter two employed in both ER and SE modes, were applied following the respective manufacturer's instructions. Composite buildups (8×8×8mm) were made using Filtek Supreme XTE (3M) prior to 1-week storage in artificial saliva. After the teeth were sectioned into mini-specimens (1.5×2.0×18mm), a single notch was prepared at the adhesive-dentin interface. Half of the specimens were immediately loaded until failure by 4-point bending to determine the mini-iFT, while the remaining specimen set was tested upon 6-month aging. Data were statistically analyzed with a linear model (p0.05).No significant decrease in mini-iFT was noted only for PA (p0.05), while the mini-iFT decreased for both other cross-linkers and in quite a similar way as when solely water (Wa) was applied.The cross-linker proanthocyanidin (PA) applied in clinically relevant conditions was able to maintain a stable mini-iFT after 6-month aging. The incorporation of UVA-activated riboflavin (RB) and glutaraldehyde (GA) in the dentin-bonding protocol appeared not effective to improve the stability of adhesive-dentin interfaces.

Details

ISSN :
01095641
Volume :
34
Database :
OpenAIRE
Journal :
Dental Materials
Accession number :
edsair.doi.dedup.....b58e7cfef3632b8c76f6bae535ea74ca
Full Text :
https://doi.org/10.1016/j.dental.2018.08.303