Back to Search
Start Over
Analysis of bone architecture using fractal-based TX-Analyzer™ in adult patients with osteogenesis imperfecta
- Source :
- Bone. 147
- Publication Year :
- 2020
-
Abstract
- Osteogenesis imperfecta (OI) is a rare genetic disorder characterized by impaired bone quality and quantity. Established imaging techniques have limited reliability in OI. The TX-Analyzer™ is a new, fractal-based software allowing a non-invasive assessment of bone structure based on conventional radiographs. We explored whether the TX-Analyzer™ can discriminate OI patients and healthy controls. Furthermore, we investigated the correlation between TX-Analyzer™ parameters and (i) bone mineral density (BMD) by Dual Energy X-ray Absorptiometry (DXA), (ii) trabecular bone score (TBS), and (iii) bone microstructure by high-resolution peripheral quantitative computed tomography (HR-pQCT).Data of 29 adult OI patients were retrospectively analyzed. Standard radiographs of the thoracic and lumbar spine were evaluated using the TX-Analyzer™. Bone Structure Value (BSV), Bone Variance Value (BVV), and Bone Entropy Value (BEV) were measured at the vertebral bodies T7 to L5. Data were compared to a healthy, age- and gender-matched control group (n = 58). BMD by DXA, TBS, and trabecular bone microstructure by means of HR-pQCT were correlated to TX-Analyzer™ parameters in OI patients. The accuracy of the TX-Analyzer™ parameters in detecting OI was assessed with area under curve (AUC) analysis of receiver operating characteristic (ROC).BEV of the thoracic and the lumbar spine were significantly lower in OI patients compared to controls (both p 0.001). BEV of the thoracic spine was significantly correlated to TBS (ρ = 0.427, p = 0.042) as well as trabecular number (Tb.N) at the radius (ρ = 0.603, p = 0.029) and inhomogeneity of the trabecular network (Tb.1/N.SD) at the radius (ρ = -0.610, p = 0.027), when assessed by HR-pQCT. No correlations were found between BEV and BMD by DXA. BEV of the thoracic and the lumbar spine had an AUC of 0.81 (95% confidence interval [CI] 0.67-0.94, p 0.001) and 0.73 (95% CI 0.56-0.89, p = 0.008), respectively. BSV and BVV did not differ between OI patients and controls.The software TX-Analyzer™ is able to discriminate patients with OI from healthy controls. ROC curves of BEV values suggest a suitable clinical applicability. Low to no correlations with conventional methods suggest, that the TX-Analyzer™ may indicate a new and independent examination tool in OI.
- Subjects :
- 0301 basic medicine
Adult
Histology
Physiology
Endocrinology, Diabetes and Metabolism
Radiography
030209 endocrinology & metabolism
03 medical and health sciences
0302 clinical medicine
Trabecular bone score
Absorptiometry, Photon
Bone Density
Medicine
Humans
Quantitative computed tomography
Retrospective Studies
Bone mineral
Adult patients
medicine.diagnostic_test
Receiver operating characteristic
business.industry
Reproducibility of Results
Osteogenesis Imperfecta
medicine.disease
030104 developmental biology
Fractals
Osteogenesis imperfecta
Lumbar spine
business
Nuclear medicine
Subjects
Details
- ISSN :
- 18732763
- Volume :
- 147
- Database :
- OpenAIRE
- Journal :
- Bone
- Accession number :
- edsair.doi.dedup.....b3a7034c605649c9cec8bed033134b5e