Back to Search Start Over

Deep feature loss to denoise OCT images using deep neural networks

Authors :
Di Xiao
Jason Kugelman
David Alonso-Caneiro
Maryam Mehdizadeh
Cara MacNish
Mohammed Bennamoun
Source :
Journal of Biomedical Optics
Publication Year :
2021
Publisher :
SPIE-Intl Soc Optical Eng, 2021.

Abstract

Significance: Speckle noise is an inherent limitation of optical coherence tomography (OCT) images that makes clinical interpretation challenging. The recent emergence of deep learning could offer a reliable method to reduce noise in OCT images. Aim: We sought to investigate the use of deep features (VGG) to limit the effect of blurriness and increase perceptual sharpness and to evaluate its impact on the performance of OCT image denoising (DnCNN). Approach: Fifty-one macula-centered OCT pairs were used in training of the network. Another set of 20 OCT pair was used for testing. The DnCNN model was cascaded with a VGG network that acted as a perceptual loss function instead of the traditional losses of L1 and L2. The VGG network remains fixed during the training process. We focused on the individual layers of the VGG-16 network to decipher the contribution of each distinctive layer as a loss function to produce denoised OCT images that were perceptually sharp and that preserved the faint features (retinal layer boundaries) essential for interpretation. The peak signal-to-noise ratio (PSNR), edge-preserving index, and no-reference image sharpness/blurriness [perceptual sharpness index (PSI), just noticeable blur (JNB), and spectral and spatial sharpness measure (S3)] metrics were used to compare deep feature losses with the traditional losses. Results: The deep feature loss produced images with high perceptual sharpness measures at the cost of less smoothness (PSNR) in OCT images. The deep feature loss outperformed the traditional losses (L1 and L2) for all of the evaluation metrics except for PSNR. The PSI, S3, and JNB estimates of deep feature loss performance were 0.31, 0.30, and 16.53, respectively. For L1 and L2 losses performance, the PSI, S3, and JNB were 0.21 and 0.21, 0.17 and 0.16, and 14.46 and 14.34, respectively. Conclusions: We demonstrate the potential of deep feature loss in denoising OCT images. Our preliminary findings suggest research directions for further investigation.

Details

ISSN :
10833668
Volume :
26
Database :
OpenAIRE
Journal :
Journal of Biomedical Optics
Accession number :
edsair.doi.dedup.....b342319d6f254955be6ef7b8cc46cb38