Back to Search
Start Over
High-Precision Position-Specific Isotope Analysis of 13C/12C in Leucine and Methionine Analogues
- Source :
- Analytical Chemistry. 75:5495-5503
- Publication Year :
- 2003
- Publisher :
- American Chemical Society (ACS), 2003.
-
Abstract
- We report an automated method for high-precision position-specific isotope analysis (PSIA) of carbon in amino acid analogues. Carbon isotope ratios are measured for gas-phase pyrolysis fragments from multiple sources of 3-methylthiopropylamine (3MTP) and isoamylamine (IAA), the decarboxylated analogues of methionine and leucine, using a home-built gas chromatography (GC)-pyrolysis-GC preparation system coupled to a combustion-isotope ratio mass spectrometry system. Over a temperature range of 620-900 degrees C, the characteristic pyrolysis products for 3MTP were CH4, C2H6, HCN, and CH3CN and for IAA products were propylene, isobutylene, HCN, and CH3CN. Fragment origin was confirmed by 13C-labeling, and fragments used for isotope analysis were generated from unique moieties with > 95% structural fidelity. Isotope ratios for the fragments were determined with an average precision of SD(delta13C) < 0.3% per thousand, and relative isotope ratios of fragments from different sources were determined with an average precision of SD(delta(delta)13C) < 0.5% per thousand. Delta(delta)13C values of fragments were invariant over a range of pyrolysis temperatures. The delta(delta)13C of complementary fragments in IAA was within 0.8% per thousand of the delta(delta)13C of the parent compounds, indicating that pyrolysis-induced isotopic fractionation is effectively taken into account with this calibration procedure. Using delta(delta)13C values of fragments, delta(delta)13C values were determined for all four carbon positions of 3MTP and for C1, C2, and the propyl moiety of IAA, either directly or indirectly by mass balance. Large variations in position-specific isotope ratios were observed in samples from different commercial sources. Most dramatically, two 3MTP sources differed by 16.30% per thousand at C1, 48.33% per thousand at C2, 0.37% per thousand at C3, and 5.36% per thousand at C(methyl). These PSIA techniques are suitable for studying subtle changes in intramolecular isotope ratios due to natural processes.
- Subjects :
- Delta
Acetonitriles
Chromatography, Gas
Hot Temperature
Analytical chemistry
chemistry.chemical_element
Fractionation
Alkenes
Mass spectrometry
Gas Chromatography-Mass Spectrometry
Analytical Chemistry
Methionine
Leucine
Hydrogen Cyanide
Amines
Isotope analysis
Carbon Isotopes
Molecular Structure
Propylamines
Isotope
Chemistry
Temperature
Ethylenes
Isotopes of carbon
Carbon Disulfide
Gas chromatography
Methane
Carbon
Algorithms
Subjects
Details
- ISSN :
- 15206882 and 00032700
- Volume :
- 75
- Database :
- OpenAIRE
- Journal :
- Analytical Chemistry
- Accession number :
- edsair.doi.dedup.....b2bc50709dc98403384204af49ccd9de
- Full Text :
- https://doi.org/10.1021/ac0344889