Back to Search
Start Over
Optical flow and image segmentation analysis for noninvasive precise mapping of microwave thermal ablation in X-ray CT scans - ex vivo study
- Source :
- International Journal of Hyperthermia. 34:744-755
- Publication Year :
- 2017
- Publisher :
- Informa UK Limited, 2017.
-
Abstract
- To develop image processing algorithms for noninvasive mapping of microwave thermal ablation using X-ray CT.Ten specimens of bovine liver were subjected to microwave ablation (20-80 W, 8 min) while scanned by X-ray CT at 5 s intervals. Specimens were cut and manually traced by two observers. Two algorithms were developed and implemented to map the ablation zone. The first algorithm utilises images segmentation of Hounsfield units changes (ISHU). The second algorithm utilises radial optical flow (ROF). Algorithm sensitivity to spatiotemporal under-sampling was assessed by decreasing the acquisition rate and reducing the number of acquired projections used for image reconstruction in order to evaluate the feasibility of implementing radiation reduction techniques.The average radial discrepancy between the ISHU and ROF contours and the manual tracing were 1.04±0.74 and 1.16±0.79mm, respectively. When diluting the input data, the ISHU algorithm retained its accuracy, ranging from 1.04 to 1.79mm. By contrast, the ROF algorithm performance became inconsistent at low acquisition rates. Both algorithms were not sensitive to projections reduction, (ISHU: 1.24±0.83mm, ROF: 1.53±1.15mm, for reduction by eight fold). Ablations near large blood vessels affected the ROF algorithm performance (1.83±1.30mm; p 0.01), whereas ISHU performance remained the same.The two suggested noninvasive ablation mapping algorithms can provide highly accurate contouring of the ablation zone at low scan rates. The ISHU algorithm may be more suitable for clinical practice as it appears more robust when radiation dose reduction strategies are employed and when the ablation zone is near large blood vessels.
- Subjects :
- Ablation Techniques
Cancer Research
Materials science
Physiology
business.industry
Optical Imaging
Microwave ablation
X-ray
Thermal ablation
Optical flow
Image segmentation
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Optics
030220 oncology & carcinogenesis
Physiology (medical)
Digital image processing
Humans
Microwaves
Tomography, X-Ray Computed
business
Microwave
Ex vivo
Subjects
Details
- ISSN :
- 14645157 and 02656736
- Volume :
- 34
- Database :
- OpenAIRE
- Journal :
- International Journal of Hyperthermia
- Accession number :
- edsair.doi.dedup.....b1c94d3c6e45292d0b1b4c8c71cd3bb1
- Full Text :
- https://doi.org/10.1080/02656736.2017.1375160