Back to Search Start Over

A single-center, self-controlled, phase I clinical trial of mitoxantrone hydrochloride injection for lymph tracing for sentinel lymph node identification of breast cancer

Authors :
Zhebin Liu
Benlong Yang
Guangyu Liu
Zhimin Shao
Jiong Wu
Shujun Wang
Shuyue Zheng
Xiaoyan Huang
Jiajian Chen
Source :
Gland Surg
Publication Year :
2021
Publisher :
AME Publishing Company, 2021.

Abstract

Background Mitoxantrone hydrochloride injection for lymph tracing (MHI) is a novel lymphatic tracer for sentinel lymph node (SLN) in patients with early breast cancer but exhibited remarkable liver, kidney, and hematologic toxicities in previous studies. Here, the pharmacokinetics and pharmacodynamics profiles of MHI were evaluated to surmise safety and tolerability. Methods Phase 1 open-label, single center, and dose escalation study was performed. Ten patients with invasive breast cancer received 0.5, 1.0, or 2.0 mL of MHI into the breast tissues surrounding the tumor for lymphatic mapping. All of these patients were injected with 2 mCi nuclide-labeled sulfur colloid as a self-control 24 to 48 hours before surgery. Safety was assessed by the incidence of adverse events graded by the National Cancer Institute Common Terminology Criteria, version 4.0.3 (CTCAE4.0.3). Blood samples for pharmacokinetic analyses were collected before and after administration at 15, 30, 60, 120, and 240 min of the injection of MHI. Results Up to the cutoff date of the study (Aug 8, 2018), no dose-limiting toxic effects or obvious allergic reactions were observed. Only one case of an adverse event was certainly related to MHI, where it caused blue discoloration of the local skin over the injection site after the operation, but this stain gradually went away. The peak level of MHI was achieved after 15-30 min post injection and completely eliminated from the plasma after 60 min. There were no significant differences in the number of lymph nodes detected by MHI and radioactive colloid. Only one patient with lymph node macrometastases had no SLN detected by either the radioactive colloid or the MHI. Conclusions At a dose of up to 2.0 mL, MHI was well tolerated and safe for conducting SLN biopsies in patients with breast cancer. Although there was a case with blue discoloration of the local skin over the injection site after the operation, and remained for a short period of time, but the overall safety was acceptable. Here, we approached a novel SLN tracing slant; however, more investigations of MHI should be performed for further evaluations. (Chinadrugtrials.org.cn number: CXHL1301201, Date of registration: October 12, 2015.).

Details

ISSN :
22278575 and 2227684X
Volume :
10
Database :
OpenAIRE
Journal :
Gland Surgery
Accession number :
edsair.doi.dedup.....b02eab51cf79a10f01207132c03e75e0
Full Text :
https://doi.org/10.21037/gs-20-694