Back to Search Start Over

Effects of breathing patterns on mechanically ventilated patients with chronic obstructive pulmonary disease and dynamic hyperinflation

Authors :
K Markopoulou
Nicholas R. Anthonisen
D Patakas
Dimitris Georgopoulos
I Mitrouska
Source :
Intensive care medicine. 21(11)
Publication Year :
1995

Abstract

To examine the circulatory and respiratory effects of breathing pattern in patients with chronic obstructive pulmonary disease (COPD) and dynamic hyperinflation (DH) during controlled mechanical ventilation. Prospective, controlled, randomized, non-blinded study. Respiratory intensive care unit of a university hospital. Nine patients with acute respiratory failure and DH due to acute exacerbations of COPD. Keeping tidal volume and total breath duration (TTOT) constant, patients were ventilated at six different values of expiratory time (TE). TE changes were randomly induced by alterations of constant inspiratory flow $$\left( {\dot V_1 } \right)$$ and/or end-inspiratory pause (EIP). Patients were studied at three levels of $$\dot V_1 $$ (0.93±0.08, 0.72±0.06 and 0.55±0.04 l/s, mean ±SE), with and without EIP (10% of TTOT). Lung volumes, airflows, airways pressures, oxygenation indices and dead space were measured. Alveolar pressure and airway resistance (Rmin), as well as the additional resistance (δR) due to viscoelastic pressure dissipation and time-constant inequalities, were estimated by rapid airway occlusion during inflation. In seven out of nine patients, right-heart catheterization was performed and hemodynamic parameters were obtained at each value of TE. A significant decrease of intrinsic positive end-expiratory pressure (PEEPi), end-inspiratory static and mean (mPaw) airway pressures, end-expiratory lung volume above passive FRC (Vtrap), δR and venous admixture and a significant increase of peak airway pressure, Rmin, stroke volume index and mixed venous PO2 $$\left( {P\bar vO_2 } \right)$$ were observed when $$\dot V_1 $$ increased. At each $$\dot V_1 $$ , the addition of EIP significantly decreased iso-volume expiratory flows and $$P\bar vO_2 $$ and increased Vtrap and mPaw. We conclude that in mechanically ventilated patients with COPD, the pattern of lung inflation and TE alteration have a significant impact on respiratory system mechanics, gas exchange and hemodynamics. Addition of EIP in patients with COPD may be detrimental.

Details

ISSN :
03424642
Volume :
21
Issue :
11
Database :
OpenAIRE
Journal :
Intensive care medicine
Accession number :
edsair.doi.dedup.....aed8b5a7205815ce3b59bf0c61e5b3ee