Back to Search
Start Over
Intraoperative Fluorescein Staining of Cryopreserved Amniotic Membrane Grafts to Improve Visualization During and After Pterygium Surgery
- Source :
- Cornea
- Publication Year :
- 2016
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2016.
-
Abstract
- Supplemental Digital Content is Available in the Text.<br />Purpose: To describe a new method of enhancing the visualization of amniotic membrane grafts with fluorescein staining during pterygium surgery. Methods: Pterygium excision surgery using intraoperatively stained cryopreserved amniotic membranes was performed on 346 eyes. A sterile 0.6 mg sodium fluorescein strip was placed directly onto the amniotic membrane in the manufacturer's original packaging, and the stained allograft was then transplanted onto the planned site. Staining intensities, at 3, 5, and 10 minutes of dye immersion, were compared. Immediate postoperative pain rating (scale 0–10), visibility of the fluorescein-stained amniotic membrane graft, and conjunctival autograft and amniotic membrane graft elevation, dehiscence, retraction, or displacement were recorded. The recurrence rate of the study population was compared with that of a previous cohort of 121 patients who underwent pterygium excision with conjunctival autograft without stained amniotic membrane. Results: Direct contact of the fluorescein strip on the amniotic membrane at 3, 5, and 10 minutes showed no differences in subjective staining intensity. Fluorescein-stained amniotic membrane was easily detected on the ocular surface during and 24 hours after pterygium surgery. The average immediate postoperative pain rating was 0.8 ± 1.8. No intraoperative complications or postoperative amniotic membrane graft dehiscence, retraction, or displacement occurred. The recurrence rate using fluorescein-stained amniotic membrane (3 patients, 0.9%, mean follow-up time 31.8 ± 18.6 weeks) did not differ from that of the previous cohort without the stained amniotic membrane (2.5%; χ2(1) = 1.837, P = 0.183). Conclusions: Fluorescein strip staining of the amniotic membrane is a novel and safe intraoperative method to enhance visualization and handling of the graft during and after ocular surgeries.
- Subjects :
- Adult
Male
medicine.medical_specialty
fluorescein
Pterygium surgery
Ophthalmologic Surgical Procedures
Dehiscence
Pterygium
Cryopreservation
Intraoperative Period
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
medicine
Humans
0601 history and archaeology
Amnion
Fluorescein
Fluorescent Dyes
Retrospective Studies
060101 anthropology
amniotic membrane
business.industry
06 humanities and the arts
Techniques
eye diseases
Surgery
Staining
Ophthalmology
medicine.anatomical_structure
Membrane
chemistry
ComputingMethodologies_DOCUMENTANDTEXTPROCESSING
030221 ophthalmology & optometry
Female
business
Subjects
Details
- ISSN :
- 02773740
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Cornea
- Accession number :
- edsair.doi.dedup.....acbd46ec7b0ed31d8d8a179b8f5481cf
- Full Text :
- https://doi.org/10.1097/ico.0000000000000725