Back to Search
Start Over
Short-term results in canines of novel stent-graft design for chimney technique in TEVAR
- Source :
- Journal of Interventional Medicine, Vol 3, Iss 3, Pp 128-131 (2020), Journal of Interventional Medicine
- Publication Year :
- 2020
- Publisher :
- KeAi Communications Co., Ltd., 2020.
-
Abstract
- Introduction Parallel stent-stent grafting is a major endovascular technique used to preserve the supra-aortic branches during thoracic endovascular aortic repair (TEVAR) of aortic pathologies involving the aortic arch. The short- and mid-term results of this technique are satisfactory; however, endoleak remains a major concern. Thus, here we designed a new chimney stent-graft to decrease the endoleak rate. Aim To testify the feasibility and safety of the new chimney stent-graft system in a canine model. Material and methods Six Labrador retrievers were used. Pre-operative data were collected and all operations were performed under general anesthesia. The main and chimney stent-grafts were implanted through the abdominal aorta and left subclavian artery approaches, respectively. Completion digital subtraction angiography (DSA) was performed to confirm the immediate outcomes. All dogs were fed separately for 6 months and sacrificed after aortic angiography. The thoracic aorta and the main and chimney stent-grafts were harvested for histopathologic examination. Results No complications were found in follow-up DSA. All branch arteries were patent. Inflammatory responses were observed around the stent-grafts in 3 experimental animals, and slight hyperplasia was observed in the surrounding tissues compared with the normal vessels. There was no mural thrombus in the stent, endothelial cells were noted on the inner surface of the stent, and thrombus was formed in the outer skirt and gutter area. The histopathologic examinations revealed similar results to those of gross necropsy observations. Conclusions This study demonstrated the feasibility and safety of the Longuette stent-graft and the first to report a revised stent-graft specific for chimney technique.
- Subjects :
- Aortic arch
medicine.medical_specialty
medicine.medical_treatment
Thoracic endovascular aortic repair
lcsh:Medicine
In vivo experiment
Article
medicine.artery
medicine
Thoracic aorta
Chimney
cardiovascular diseases
Stent-graft
Thrombus
medicine.diagnostic_test
business.industry
Abdominal aorta
lcsh:R
Stent
Digital subtraction angiography
medicine.disease
equipment and supplies
surgical procedures, operative
Angiography
cardiovascular system
Chimney technique
Radiology
business
Canine model
Subjects
Details
- Language :
- English
- ISSN :
- 20963602
- Volume :
- 3
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Journal of Interventional Medicine
- Accession number :
- edsair.doi.dedup.....ac4a9e60460f71fdf9b621b3b746b3aa