Back to Search
Start Over
Rapid Detection of Mycoplasma pneumoniae by Loop-Mediated Isothermal Amplification (LAMP) in Clinical Respiratory Specimens
- Source :
- Iranian Journal of Public Health, Vol 48, Iss 5 (2019), Iranian Journal of Public Health, Scopus-Elsevier
- Publication Year :
- 2019
- Publisher :
- Knowledge E, 2019.
-
Abstract
- Background: Mycoplasma pneumoniae is a common cause of community-acquired pneumonia (CAP) worldwide, especially among children and debilitated populations. The present study aimed to investigate a loop-mediated isothermal amplification (LAMP) technique for rapid detection of M. pneumoniae in clini-cal specimens collected from patients with pneumonia. Methods: Throat swabs were collected from 110 outpatients who suffered from pneumonia. Throat swab samples were obtained from patients referred to the hospital outpatient clinics of Tehran University hospitals, Iran in 2017. The presence of M. pneumoniae in the clinical specimens was evaluated by LAMP, PCR and culture methods. Sensitivity and specificity of the LAMP and PCR assays were also determined. Results: Out of 110 specimens, LAMP assay detected M. pneumoniae in 35 specimens. Detection limit of the LAMP assay was determined to be 33fg /μL or ~ 40 genome copies/reaction. Moreover, no cross-reaction with genomic DNA from other bacteria was observed. Only 25 specimens were positive by the culture method. The congruence between LAMP assay and culture method was ‘substantial’ (κ=0.77). Specificity and sensitivity of LAMP assay were 88.2%, 100% in compare with culture. However, the con-gruence between LAMP assay and PCR assay was ‘almost perfect’ (κ=0.86). Specificity and sensitivity of LAMP assay were 92.5%, 100% in compare with PCR. Conclusion: Overall, the LAMP assay is a rapid and cost-efficient laboratory test in comparison to other methods including PCR and culture. Therefore, the LAMP method can be applied in identification of M. pneumoniae isolates in respiratory specimens.
- Subjects :
- Mycoplasma pneumoniae
Loop-mediated isothermal amplification (LAMP)
Culture
Loop-mediated isothermal amplification
medicine.disease_cause
Rapid detection
Microbiology
03 medical and health sciences
0302 clinical medicine
Throat
medicine
Outpatient clinic
030212 general & internal medicine
Respiratory system
030505 public health
business.industry
lcsh:Public aspects of medicine
Public Health, Environmental and Occupational Health
lcsh:RA1-1270
medicine.disease
University hospital
eye diseases
Pneumonia
PCR
medicine.anatomical_structure
Original Article
sense organs
0305 other medical science
business
Subjects
Details
- ISSN :
- 22516093 and 22516085
- Database :
- OpenAIRE
- Journal :
- Iranian Journal of Public Health
- Accession number :
- edsair.doi.dedup.....ac2cb511b68d9348057fabd8325077fa