Dynamic contour tonometry: handheld versus slit-lamp-mounted
- Source :
- Ophthalmology. 116(8)
- Publication Year :
- 2008
-
Abstract
- Purpose To compare the newly developed handheld dynamic contour tonometer (hh-DCT) with the established slit-lamp–mounted DCT (sl-DCT) in terms of agreement for intraocular pressure (IOP) and ocular pulse amplitude (OPA) measurements, intraobserver variability, and tonography effect. Design Evaluation of diagnostic technology. Participants Fifty eyes of 50 healthy volunteers were examined with the hh-DCT and sl-DCT. Methods A paired t test was performed to analyze differences in IOP and OPA readings. Measurements were compared for bias and agreement according to the method of Bland and Altman. Intraclass correlation coefficients (ICCs) were calculated to compare intraobserver variability. A mixed model analysis was performed to assess a possible tonography effect. Main Outcome Measures The differences in IOP and OPA measurements, intraobserver variability, and tonography effect between the hh-DCT and the sl-DCT were examined. Results No statistically significant differences in IOP (sl-DCT−hh-DCT: 0.1±1.43 mmHg, 95% confidence interval [CI], −0.31 to 0.5, P = 0.63) or OPA (sl-DCT−hh-DCT: −0.1±0.52 mmHg, 95% CI, −0.28 to 0.01, P = 0.08) measurements were detected. Bland-Altman analysis revealed a bias of 0.1 with the limits of agreement of IOP measurement differences ranging from −2.71 to +2.90 mmHg. With regard to IOP readings obtained by sl-DCT, hh-DCT overestimated IOPs less than 15.6 mmHg and underestimated IOPs more than 15.6 mmHg. ICCs calculated for IOP readings were 0.87 (95% CI, 0.8–0.92) for hh-DCT and 0.85 (95% CI, 0.78–0.90) for sl-DCT. ICCs for OPA readings were 0.86 (95% CI, 0.79–0.91) for hh-DCT and 0.87 (95% CI, 0.8–0.91) for sl-DCT. Comparing the ICCs revealed no statistically significant difference between the devices with regard to IOP and OPA measurements ( P = 0.53 and P = 0.93, respectively). Mixed model analysis of 3 consecutive IOP measurements revealed a decrease in IOP of 0.5 mmHg after each measurement in both devices, which was not significant between the 2 methods ( P = 0.68). Conclusions IOP and OPA readings obtained by the novel hh-DCT were shown to be strongly concordant with measurements obtained by the sl-DCT device. The hh-DCT may be a valuable alternative to the sl-DCT in clinical practice. Financial Disclosure(s) The author(s) have no proprietary or commercial interest in any materials discussed in this article.
- Subjects :
- Adult
Male
medicine.medical_specialty
Intraocular pressure
genetic structures
Design evaluation
Adolescent
Intraclass correlation
Sensitivity and Specificity
Tonometry, Ocular
Young Adult
Ophthalmology
medicine
Humans
Prospective Studies
Intraocular Pressure
Observer Variation
Slit lamp
business.industry
Significant difference
Limits of agreement
Reproducibility of Results
Middle Aged
eye diseases
Confidence interval
body regions
Optometry
Female
business
Student's t-test
Subjects
Details
- ISSN :
- 15494713
- Volume :
- 116
- Issue :
- 8
- Database :
- OpenAIRE
- Journal :
- Ophthalmology
- Accession number :
- edsair.doi.dedup.....aaec54b59973ef503e16927b8b71b52b