Back to Search
Start Over
Reproducibility of Nerve Fiber Layer Thickness Measurements Using Optical Coherence Tomography
- Source :
- Ophthalmology. 103:1889-1898
- Publication Year :
- 1996
- Publisher :
- Elsevier BV, 1996.
-
Abstract
- Purpose: Optical coherence tomography (OCT) is a new technology that uses near-infrared light in an interferometer to produce approximately 10-µm resolution crosssectional images of the tissue of interest. The authors performed repeated quantitative assessment of nerve fiber layer thickness in individuals with normal and glaucomatous eyes, and they evaluated the reproducibility of these measurements. Methods: The authors studied 21 eyes of 21 subjects by OCT. Each subject underwent five repetitions of a series of scans on five separate occasions within a 1-month period. Each series consisted of three circular scans around the optic nerve head (diameters, 2.9, 3.4, and 4.5 mm). Each series was performed separately using internal (fixation with same eye being studied) and external (fixation with contralateral eye) fixation techniques. The eye studied and the sequence of testing were assigned randomly. Results: Internal fixation (IF), in general, provides a slightly higher degree of reproducibility than external fixation (EF). Reproducibility was better in a given eye on a given visit than from visit to visit. Reproducibility as measured by intraclass correlation coefficients were as follows: circle diameter (CD), 2.9 mm, 0.51/0.57 (normal/glaucoma) (IF), 0.43/0.54 (EF); CD, 3.4 mm, 0.56/0.52 (IF), 0.43/0.61 (EF); CD, 4.5 mm, 0.53/0.43 (IF), 0.42/0.49 (EF). Conclusions: Nerve fiber layer thickness can be reproducibly measured using OCT. Internal is superior to external fixation; each circle diameter tested provides adequate reproducibility.
- Subjects :
- Male
genetic structures
Fundus Oculi
medicine.medical_treatment
Nerve fiber layer
Glaucoma
Nerve fiber
Retina
Article
Fixation (surgical)
External fixation
Nerve Fibers
Optical coherence tomography
Image Processing, Computer-Assisted
medicine
Humans
Internal fixation
Tomography
Aged
Reproducibility
medicine.diagnostic_test
business.industry
Reproducibility of Results
Optic Nerve
Anatomy
medicine.disease
eye diseases
Ophthalmology
medicine.anatomical_structure
Female
Visual Fields
business
Nuclear medicine
Subjects
Details
- ISSN :
- 01616420
- Volume :
- 103
- Database :
- OpenAIRE
- Journal :
- Ophthalmology
- Accession number :
- edsair.doi.dedup.....aac6463c56850f5f17fce1c23fbfe14c
- Full Text :
- https://doi.org/10.1016/s0161-6420(96)30410-7