Back to Search
Start Over
Impact of TPS calculation algorithms on dose delivered to the patient in proton therapy treatments
- Source :
- Physics in medicine and biology. 64(7)
- Publication Year :
- 2019
-
Abstract
- To estimate the impact of dose calculation approaches adopted in different treatment planning systems (TPSs) on proton therapy dose delivered with pencil beam scanning (PBS). Treatment plans for six regular volumes in water and 15 clinical cases were optimized with Syngo-VC13 and exported for forward recalculation with Raystation-V7.0 pencil beam (RS-PBA) and Monte Carlo (RS-MC) algorithms and with the independent Fluka-MC engine. To verify clinical consistency between the two TPS dosimetric outcomes, the average percentage variations of clinical target volume (CTV) D 98%, D 50% and D 2%, adopted for plan prescription and evaluation, were considered. Ionization chamber measurements served as a further reference for comparison in homogeneous conditions. CTV dose volume histogram (DVH) analysis and gamma evaluation with 3 mm-3% agreement criteria quantified the dose deviation of TPS calculation algorithms, in heterogeneous conditions, against the Fluka-MC code. CTV D 50%, representing the plan dose prescription goal, was higher on average over H&N cases of (3.9 ± 0.9)% and (2.3 ± 0.6)% as calculated with RS-PBA and RS-MC, respectively, compared to Syngo. For tumors located in the pelvis district, average D 50% variations of (1.6 ± 0.7)% and (1.2 ± 0.7)% were found. Syngo underestimated target near maximum doses with respect to all computation systems. Calculation accuracy in heterogeneous conditions of RS-PBA H&N plans resulted poor when a range shifter was required. Target DVH and γ-analysis showed excellent agreement between RS-MC and Fluka-MC, with γ-pass rates >98% for all patient groups. Different TPS dose calculation approaches mainly affected dose delivered in H&N proton treatments, while minor deviations were found for pelvic tumors. RS-MC proved to be the most accurate TPS dose calculation algorithm when compared to an independent MC simulation code.
- Subjects :
- Dose-volume histogram
Monte Carlo method
030218 nuclear medicine & medical imaging
03 medical and health sciences
Dose calculation algorithm
0302 clinical medicine
Proton Therapy
Humans
Radiology, Nuclear Medicine and imaging
Radiation treatment planning
Pencil-beam scanning
Radiometry
Proton therapy
Mathematics
Pelvic Neoplasms
Radiological and Ultrasound Technology
business.industry
Radiotherapy Planning, Computer-Assisted
Calculation algorithm
Radiotherapy Dosage
Head and Neck Neoplasms
030220 oncology & carcinogenesis
Ionization chamber
Nuclear medicine
business
Monte Carlo Method
Algorithms
Subjects
Details
- ISSN :
- 13616560
- Volume :
- 64
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Physics in medicine and biology
- Accession number :
- edsair.doi.dedup.....aa50589fd606f1a8b51c90d854a8e537