Back to Search Start Over

High-Resolution Infrared Thermography of Esophageal Temperature During Radiofrequency Ablation of Atrial Fibrillation

Authors :
Graham Roper
Iain Melton
M. Daly
Ian Crozier
Gary Lim
Source :
Circulation: Arrhythmia and Electrophysiology. 11
Publication Year :
2018
Publisher :
Ovid Technologies (Wolters Kluwer Health), 2018.

Abstract

Background: Catheter ablation for atrial fibrillation has potential to cause esophageal thermal injury. Esophageal temperature monitoring during ablation is commonly used; however, it has not eliminated thermal injuries, possibly because conventional sensors have poor spatial sampling and response characteristics. To enhance understanding of temperature dynamics that may underlie esophageal injury, we tested a high-resolution, intrabody, infrared thermography catheter to continuously image esophageal temperatures during ablation. Methods and Results: Atrial fibrillation ablation patients were instrumented with a flexible, 9F infrared temperature catheter inserted nasally (n=8) or orally (n=8) into the esophagus adjacent to the left atrium. Ablation was performed while the infrared catheter continuously recorded surface temperatures from 7680 points per second circumferentially over a 6-cm length of esophagus. Physicians were blinded to temperature data. Endoscopy was performed within 24 hours to document esophageal injury. Thermal imaging showed that most patients (10/16) experienced ≥1 events where peak esophageal temperature was >40°C. Three patients experienced temperatures >50°C; and 1 experienced >60°C. Analysis of temperature data for each subject’s maximum thermal event revealed high gradients (2.3±1.4°C/mm) and rates of change (1.5±1.3°C/s) with an average length of esophageal involvement of 11.0±5.4 mm. Endoscopy identified 3 distinct thermal lesions, all in patients with temperatures >50°C; all resolved within 2 weeks. Conclusions: Infrared thermography provided dynamic, high-resolution mapping of esophageal temperatures during cardiac ablation. Esophageal thermal injury occurred with temperatures >50°C and was associated with large spatiotemporal gradients. Additional studies are warranted to determine the relationships between thermal parameters and esophageal injury.

Details

ISSN :
19413084 and 19413149
Volume :
11
Database :
OpenAIRE
Journal :
Circulation: Arrhythmia and Electrophysiology
Accession number :
edsair.doi.dedup.....a9a308553019cb1a580a3b35b7766269
Full Text :
https://doi.org/10.1161/circep.117.005667