Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
- Source :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 59
- Publication Year :
- 2018
-
Abstract
- Purpose The purpose of this work was to develop and validate a multileaf collimator (MLC) model for a TrueBeam™ linac using Geant4 Monte Carlo (MC) simulation kit. Methods A Geant4 application was developed to accurately represent TrueBeam™ linac. Pre-computed phase-space file in a plane just above the jaws was used for radiation transport. A Varian 120 leaf Millennium™ MLC was modeled using geometry and material specifications provided by the manufacturer using Geant4 constructs. Leaf characteristics e.g. tongue-groove design, variable thickness, interleaf gap were simulated. The linac model was validated by comparing simulated dose profiles and depth-doses with experimental data using an ionization chamber in water. Dosimetric characteristics of the MLC such as inter- and intra-leaf leakage, penumbra effect, MLC leaf positioning, and dynamic characteristics were also investigated. Results For the depth dose curves, 99% of the calculated data points agree within 1% of the experimental values for the 4 × 4 cm2 and 10 × 10 cm2 and within 2% of the experimental values for 20 × 20, 30 × 30 and 40 × 40 cm2 jaw defined fields. The cross-plane dose profiles show agreement Conclusions The TrueBeam™ linac equipped with 120-leaf MLC was successfully modeled using Geant4. The accuracy of the model was verified by comparing the simulations with experiments. The model may be utilized for independent dose verification and QA of IMRT.
- Subjects :
- Physics
Phantoms, Imaging
Radiotherapy Planning, Computer-Assisted
Monte Carlo method
Biophysics
Truebeam
General Physics and Astronomy
General Medicine
Linear particle accelerator
030218 nuclear medicine & medical imaging
Multileaf collimator
Dynamic simulation
03 medical and health sciences
0302 clinical medicine
030220 oncology & carcinogenesis
Ionization chamber
Dose verification
Radiology, Nuclear Medicine and imaging
Particle Accelerators
Radiometry
Monte Carlo Method
Simulation
Depth dose
Subjects
Details
- ISSN :
- 1724191X
- Volume :
- 59
- Database :
- OpenAIRE
- Journal :
- Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
- Accession number :
- edsair.doi.dedup.....a997fb79c9457c903b2036ce89620729