Back to Search
Start Over
Hemodynamic Response to Fluid Boluses for Hypotension in Children in a Cardiac ICU
- Source :
- Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 22(1)
- Publication Year :
- 2020
-
Abstract
- OBJECTIVES: To describe the hemodynamic response to fluid boluses for hypotension in children in a cardiac ICU. DESIGN: A prospective, observational study. SETTING: Single-centered cardiac ICU. PATIENTS: Children in a cardiac ICU with hypotension. INTERVENTIONS: Clinician prescribed fluid bolus. MEASUREMENTS AND MAIN RESULTS: Sixty-four fluid boluses were administered to 52 children. Fluid composition was 4% albumin in 36/64 (56%), 0.9% saline in 18/64 (28%), and cardiopulmonary bypass pump blood in 10/64 (16%). The median volume and duration were 5.0 mL/kg (interquartile range, 4.8-5.4) and 8 minutes (interquartile range, 4-19), respectively. Hypovolemia/low filling pressures was the most common additional indication (25/102 [25%]). Mean arterial pressure response, defined as a 10% increase from baseline, occurred in 42/64 (66%) of all fluid boluses at a median time of 6 minutes (interquartile range, 4-11). Mean arterial pressure responders had a median peak increase in the mean arterial pressure of 15 mm Hg (43 mm Hg [interquartile range, 29-50 mm Hg] to 58 mm Hg [interquartile range, 49-65 mm Hg]) at 17 minutes (interquartile range, 14-24 min) compared with 4 mm Hg (48 mm Hg [interquartile range, 40-51 mm Hg] to 52 mm Hg [interquartile range, 45-56 mm Hg]) at 10 minutes (interquartile range, 3-18 min) in nonresponders. Dissipation of mean arterial pressure response, when defined as a subsequent decrement in mean arterial pressure below 10%, 5%, and 2% increases from baseline, occurred in 28/42 (67%), 18/42 (43%), and 13/42 (31%) of mean arterial pressure responders, respectively. Cardiopulmonary bypass pump blood was strongly associated with peak change in mean arterial pressure from baseline (coefficient 11.0 [95% CI, 4.3-17.7]; p = 0.02). Fifty out of 64 (78%) were receiving a vasoactive agent. However, change in vasoactive inotrope score was not associated with change in mean arterial pressure (coefficient 2.3 [95% CI, -2.5 to -7.2]; p = 0.35). Timing from admission, nor fluid bolus duration, influenced mean arterial pressure response. CONCLUSIONS: In children with hypotension in a cardiac ICU, the median dose and duration of fluid boluses were 5 mL/kg and 8 minutes. Peak response occurred shortly following administration and commonly returned to baseline.
- Subjects :
- Mean arterial pressure
business.industry
Haemodynamic response
medicine.medical_treatment
Hemodynamics
Heart
Critical Care and Intensive Care Medicine
law.invention
Intensive Care Units
Blood pressure
law
Interquartile range
Hypovolemia
Anesthesia
Pediatrics, Perinatology and Child Health
Cardiopulmonary bypass
medicine
Humans
Prospective Studies
medicine.symptom
Hypotension
business
Child
Saline
Subjects
Details
- ISSN :
- 15297535
- Volume :
- 22
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
- Accession number :
- edsair.doi.dedup.....a95aaf9d2091c7103c63baca4c275886