Back to Search
Start Over
Evaluation of limited blood sampling population input approaches for kinetic quantification of [18F]fluorothymidine PET data
- Source :
- EJNMMI Research
- Publisher :
- Springer Nature
-
Abstract
- Background Quantification of kinetic parameters of positron emission tomography (PET) imaging agents normally requires collecting arterial blood samples which is inconvenient for patients and difficult to implement in routine clinical practice. The aim of this study was to investigate whether a population-based input function (POP-IF) reliant on only a few individual discrete samples allows accurate estimates of tumour proliferation using [18F]fluorothymidine (FLT). Methods Thirty-six historical FLT-PET data with concurrent arterial sampling were available for this study. A population average of baseline scans blood data was constructed using leave-one-out cross-validation for each scan and used in conjunction with individual blood samples. Three limited sampling protocols were investigated including, respectively, only seven (POP-IF7), five (POP-IF5) and three (POP-IF3) discrete samples of the historical dataset. Additionally, using the three-point protocol, we derived a POP-IF3M, the only input function which was not corrected for the fraction of radiolabelled metabolites present in blood. The kinetic parameter for net FLT retention at steady state, Ki, was derived using the modified Patlak plot and compared with the original full arterial set for validation. Results Small percentage differences in the area under the curve between all the POP-IFs and full arterial sampling IF was found over 60 min (4.2%-5.7%), while there were, as expected, larger differences in the peak position and peak height. A high correlation between Ki values calculated using the original arterial input function and all the population-derived IFs was observed (R2 = 0.85-0.98). The population-based input showed good intra-subject reproducibility of Ki values (R2 = 0.81-0.94) and good correlation (R2 = 0.60-0.85) with Ki-67. Conclusions Input functions generated using these simplified protocols over scan duration of 60 min estimate net PET-FLT retention with reasonable accuracy.
- Subjects :
- FLT
education.field_of_study
medicine.diagnostic_test
business.industry
Population
Input function
Tumour proliferation
18f fluorothymidine
Kinetic modelling
Positron emission tomography
Quantification
Medicine
Radiology, Nuclear Medicine and imaging
Routine clinical practice
business
Nuclear medicine
education
Cardiac imaging
Original Research
Blood sampling
Subjects
Details
- Language :
- English
- ISSN :
- 2191219X
- Volume :
- 2
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- EJNMMI Research
- Accession number :
- edsair.doi.dedup.....a8986b4aada674ade8495c3118fe6c44
- Full Text :
- https://doi.org/10.1186/2191-219x-2-11