Back to Search Start Over

Simultaneous determination of TPN729 and its five metabolites in human plasma and urine by liquid chromatography coupled to tandem mass spectrometry

Authors :
Pei Hu
Ji Jiang
Ling Song
Shuguang Shao
Dongyang Liu
Xueting Yao
Hongzhong Liu
Yang Liu
Hanlin Song
Jie Liu
Source :
Journal of Pharmaceutical and Biomedical Analysis. 151:91-105
Publication Year :
2018
Publisher :
Elsevier BV, 2018.

Abstract

A specific and sensitive method was firstly developed using high performance liquid chromatography coupled with tandem mass spectrometry (HPLC–MS/MS) to simultaneously quantify TPN729 and its metabolites (TPN729-D1, TPN729-D2, TPN729M15-3 and TPN729M3) in human plasma and (TPN729-D1, TPN729-D2, TPN729M15-3 and TPN729M14) in human urine. Protein precipitation and direct dilution were used to extract TPN729 and its metabolites from plasma and urine, respectively. Ionization of TPN729, TPN729-D1, TPN729-D2, TPN729M15-3, TPN729M3, TPN729M14 and sildenafil (internal standard, IS) was performed using an electrospray ionization (ESI) source in positive mode and detection was carried out with multiple reaction monitoring (MRM) mode. This assay method for TPN729 and its five metabolites has been fully validated in terms of sensitivity, linearity, lower limit of quantification (LLOQ), precision, accuracy, stability, matrix effect and recovery. The LLOQ of TPN729/TPN729-D1/TPN729-D2/TPN729M15-3/TPN729M3 in human plasma and TPN729/TPN729-D1/TPN729-D2/TPN729M15-3/TPN729M14 in human urine were 0.200/0.500/2.00/0.500/1.00 ng/mL and 4.00/2.50/10.0/2.50/1.00 ng/mL, respectively. Inter- and intra-batch precision of TPN729 and its metabolites were less than 15% and the accuracy was within ±15% for both plasma and urine. The extraction recoveries of all analytes at three concentration levels were consistent. In conclusion, the validation results showed that this method was robust, specific, and sensitive and it can successfully fulfill the requirement of clinical pharmacokinetic study of TPN729 in Chinese healthy subjects.

Details

ISSN :
07317085
Volume :
151
Database :
OpenAIRE
Journal :
Journal of Pharmaceutical and Biomedical Analysis
Accession number :
edsair.doi.dedup.....a6d48d815bd87ba26bee17b009f03dd7
Full Text :
https://doi.org/10.1016/j.jpba.2017.12.057