Back to Search Start Over

Assessment of chloramination control strategy based on free-ammonia concentration

Authors :
Ralph Henderson
Rolando Fabris
Christopher W.K. Chow
Dammika Vitanage
Alexander Badalyan
Skadi Motzko
Motzko, Skadi
Fabris, Rolando
Badalyan, Alexander
Henderson, Ralph
Chow, Christopher WK
Vitanage, Dammika
Source :
Journal of Water Supply: Research and Technology-Aqua. 58:29-39
Publication Year :
2009
Publisher :
IWA Publishing, 2009.

Abstract

A new approach of using free-ammonia measurements as the basis of a control strategy to optimise a chloraminated water distribution system was tested in a laboratory evaluation. A test rig with a newly developed low level on-line free-ammonia analyser was constructed to investigate two different control configurations, the currently used feedback and the proposed feedforward. The results of this trial showed that only using the free-ammonia analyser for feedback control is not ideal due to its inability to detect chlorine overdosing situations. Better results regarding the maximum yield of disinfectant residuals when using the feedforward configuration were observed, and free-ammonia concentrations below 0.065 mg/L were consistently achieved. Refereed/Peer-reviewed

Details

ISSN :
16053974 and 00037214
Volume :
58
Database :
OpenAIRE
Journal :
Journal of Water Supply: Research and Technology-Aqua
Accession number :
edsair.doi.dedup.....a69b32ce164c51e78ad4a9e6f727d087
Full Text :
https://doi.org/10.2166/aqua.2009.068