Back to Search Start Over

Don’t Trust the Imaging

Authors :
Israel M. Barbash
Shlomi Matetzky
Arsalan Abu-Much
Paul Fefer
Amit Segev
Victor Guetta
Elad Maor
Noam Nissan
Source :
JACC Case Reports, JACC: Case Reports, Vol 2, Iss 15, Pp 2339-2343 (2020)
Publication Year :
2020
Publisher :
Elsevier, 2020.

Abstract

Mesenteric ischemia is a rare but lethal complication of transcatheter aortic valve replacement (TAVR). We present a challenging case of an 80-year-old man who had abdominal pain few hours following TAVR. Repeated abdominal and pelvic imaging showed no vascular obstruction, but exploratory laparoscopy revealed a necrotic bowel. (Level of Difficulty: Intermediate.)<br />Graphical abstract