Angiographic deterioration of target coronary artery narrowing as a result of percutaneous balloon angioplasty

Authors :
Yoseph Rozenman
Dan Gilon
Yonathan Hasin
Morris Mosseri
Dan Sapoznikov
Chaim Lotan
Mervyn S. Gotsman
Source :
American heart journal. 133(5)
Publication Year :
1997

Abstract

We evaluated the long-term angiographic outcome of balloon angioplasty by comparing original and follow-up target coronary narrowing. Rather than using restenosis to determine outcome, as in most angioplasty studies, we took an unusual approach and analyzed outcome in terms that are commonly used in progression and regression studies after medical interventions. Quantitative angiographic measurements were undertaken in 315 narrowings with an initial diameter stenosis90% before and after angioplasty and at follow-up. Angiographic deterioration (10% increase in follow-up diameter stenosis) was identified in 44 (14%) narrowings. Angiographic deterioration was not influenced by age, sex, risk factors, lipid profile, or the indication for angioplasty. Deterioration was also not predicted by the severity, length, or the location of the narrowing. The deteriorating narrowings had a higher recoil after dilatation compared with narrowings with angiographic improvement (21% +/- 31% vs 12% +/- 17%, p = 0.006); the residual stenosis after angioplasty was therefore higher. The late loss was also significantly increased compared with narrowings with angiographic improvement (65% +/- 26% vs 8% +/- 24%, p0.001). We conclude that the incidence of angiographic deterioration of coronary disease as a result of restenosis is uncommon but not negligible. Interventional cardiologists should resist the temptation to dilate mild, silent coronary narrowings because the procedure might have an unfavorable angiographic (and probably clinical) effect.

Details

ISSN :
00028703
Volume :
133
Issue :
5
Database :
OpenAIRE
Journal :
American heart journal
Accession number :
edsair.doi.dedup.....a602aef9b5e385c212fb7b5fa0f9aba4